EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Establishment and application of a loop‐mediated isothermal amplification−lateral flow dipstick (LAMP–LFD) method for detecting Clostridium piliforme

Junhao Tao, Huiqiong Yan, Sisi Chen, Jiangtao Du, Shasang Zhou, Honggang Guo, Lingqun Lu, Jie Fang, Xiaoyin Jin, Zhiyuan Wang, Huazhong Ying, Wei Han iD und 1 weitere

Veterinary Medicine and Science · 2024

DOI: 10.1002/vms3.1318 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Medicine and Science, 2024. Verfasst von Junhao Tao und 12 weiteren Autor:innen. Beteiligte Einrichtung: Center of Laboratory Animal, Hangzhou Medical College, Hangzhou, China. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Eubacteriales, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Medical Science and Technology Project of Zhejiang Province, Public Welfare Technology Application Research Project of Zhejiang Province, Hangzhou Medical College Institute Special Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Clostridium piliforme (causative agent of Tyzzer disease) infects various animals, including primates, and hence a threat to animal and human health worldwide. At present, it is detected using traditional methods, such as path morphology, polymerase chain reaction and enzyme‐linked immunosorbent assay. Therefore, it is necessary to develop convenient, efficient visual molecular biological methods for detecting C. piliforme .

Objectives

To establish a method with good specificity, high sensitivity and simple operation for the detection of C. piliforme .

Methods

In this study, we designed internal and external primers based on the conserved 23S rRNA region of C. piliforme to develop a biotin‐labelled diarrhoea‐suffered loop‐mediated isothermal amplification (LAMP) system for detecting of C. piliforme and assessed the specificity, sensitivity and repeatability of the LAMP system.

Results

The LAMP system did not exhibit cross‐reactivity with 24 other common pathogenic species, indicating that it had good specificity. The minimum concentration of sensitivity was 1 × 10 −7 ng/μL. Mouse models ( Meriones unguiculatus ) of Tyzzer disease were established and a LAMP−lateral flow dipstick (LAMP–LFD) was developed for detecting C. piliforme . The detection rate of C. piliforme was 5.08% in clean‐grade animals and 9.96% in specific‐pathogen‐free‐grade animals from Jiangsu, Zhejiang and Shanghai. In addition, the detection rates of C. piliforme were 10.1%, 8.6% and 20%, in animals from Hangzhou, Wenzhou and Shaoxing, respectively. The detection rate of C. piliforme was higher in experimental animals used in schools than in those used in companies and research institutes.

Conclusions

The LAMP–LFD method established in this study can be used to detect C. piliforme in animals handled in laboratory facilities of universities, pharmaceutical enterprises and research and development institutions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesEubacterialesMolecular Diagnostic TechniquesHumansMiceAnimalsSensitivity and SpecificityChina

Stichwörter der Autor:innen

Clostridium piliformeLAMP-LFDTyzzerdiagnosisrapid detection

Autor:innen und Institutionen

  • Center of Laboratory Animal, Hangzhou Medical College, Hangzhou, China.
  • Zhejiang Provincial Key Laboratory of Laboratory Animals and Safety Research, Hangzhou Medical College, Hangzhou, China.
  • Engineering Research Center of Novel Vaccine of Zhejiang Province, Hangzhou Medical College, Hangzhou, China.

ORCID-Profile: Wei Han

Förderung

  • Medical Science and Technology Project of Zhejiang Province
  • Public Welfare Technology Application Research Project of Zhejiang Province
  • Hangzhou Medical College Institute Special Project
  • Department of Education of Zhejiang Province
  • Zhejiang Traditional Chinese Medicine Science Administration
  • Zhejiang Province Public Welfare Technology Application Research Project

Zitieren

APA

Tao, J., Yan, H., Chen, S., Du, J., Zhou, S., Guo, H., Lu, L., Fang, J., Jin, X., Wang, Z., Ying, H., Han, W., & Dai, F. (2024). Establishment and application of a loop‐mediated isothermal amplification−lateral flow dipstick (LAMP–LFD) method for detecting Clostridium piliforme. Veterinary Medicine and Science. https://doi.org/10.1002/vms3.1318

Vancouver

Tao J, Yan H, Chen S, Du J, Zhou S, Guo H, et al. Establishment and application of a loop‐mediated isothermal amplification−lateral flow dipstick (LAMP–LFD) method for detecting Clostridium piliforme. Veterinary Medicine and Science. 2024. doi:10.1002/vms3.1318

BibTeX
@article{Tao2024,
  author = {Tao, Junhao and Yan, Huiqiong and Chen, Sisi and Du, Jiangtao and Zhou, Shasang and Guo, Honggang and Lu, Lingqun and Fang, Jie and Jin, Xiaoyin and Wang, Zhiyuan and Ying, Huazhong and Han, Wei and Dai, Fangwei},
  title = {Establishment and application of a loop‐mediated isothermal amplification−lateral flow dipstick (LAMP–LFD) method for detecting Clostridium piliforme},
  journal = {Veterinary Medicine and Science},
  year = {2024},
  doi = {10.1002/vms3.1318}
}
Kostenlos starten →