EUVIMEDEUVIMED entdecken
Crossref

Voltammetry determination of Cd(II) and Pb(II) at TiO 2 /reduced graphene oxide modified electrodes

Nguyen Dinh Luyen, Tran Thanh Tam Toan, Nguyen Mau Thanh

Vietnam Journal of Chemistry · 2024-06 · 62 (3) · 361-370

DOI: 10.1002/vjch.202300303 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vietnam Journal of Chemistry, online erschienen am 15.04.2024. Verfasst von Nguyen Dinh Luyen und 2 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Bộ Giáo dục và Ðào tạo.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this article, a TiO 2 /reduced graphene oxide (rGO) composite was synthesized from rGO and soluble titanium hydroxide‐peroxide complexes. The obtained materials were characterized by X‐ray diffraction, scanning electron microscopy, nitrogen adsorption/desorption, Raman spectroscopy and energy dispersive X‐ray spectroscopy‐elementary mapping. The TiO 2 /rGO composite was used as an electrode modifier for developing an electrochemical sensor to simultaneous analysis of Cd(II) and Pb(II) by using differential pulse anodic stripping voltammetry (DP‐ASV). Under optimal conditions, the linear correlation between the stripping peak current and the metal ion concentration is good in the range of 5–100 ppb for both metals ( R 2 ≥ 0.998), and a low detection limit (3.17 ppb for Cd(II) and 2.42 ppb for Pb(II)) was obtained. The interference study revealed that some metal cations had little influence on the DP‐ASV signals of Cd(II) and Pb(II). In addition, the developed electrode exhibited satisfied reproducibility and repeatability. The TiO 2 /rGO‐modified electrode was tested toward the detection of Cd(II) and Pb(II) in river waters and the obtained exceptional recoveries and results were further associated with AAS results. This study indicates that the TiO 2 /rGO composite might be an alternative for practical applications in the electrochemical determination of heavy metal ions in aquatic solutions.

Förderung

  • Bộ Giáo dục và Ðào tạo

Zitieren

APA

Luyen, N. D., Toan, T. T. T., & Thanh, N. M. (2024). Voltammetry determination of Cd(II) and Pb(II) at TiO 2 /reduced graphene oxide modified electrodes. Vietnam Journal of Chemistry, 62(3), 361-370. https://doi.org/10.1002/vjch.202300303

Vancouver

Luyen ND, Toan TTT, Thanh NM. Voltammetry determination of Cd(II) and Pb(II) at TiO 2 /reduced graphene oxide modified electrodes. Vietnam Journal of Chemistry. 2024;62(3):361-370. doi:10.1002/vjch.202300303

BibTeX
@article{Luyen2024,
  author = {Luyen, Nguyen Dinh and Toan, Tran Thanh Tam and Thanh, Nguyen Mau},
  title = {Voltammetry determination of Cd(II) and Pb(II) at TiO 2 /reduced graphene oxide modified electrodes},
  journal = {Vietnam Journal of Chemistry},
  year = {2024},
  volume = {62},
  number = {3},
  pages = {361--370},
  doi = {10.1002/vjch.202300303}
}
Kostenlos starten →