EUVIMEDEUVIMED entdecken
Crossref

Magnetic resonance imaging of the normal feline eye using a T1‐weighted volumetric sequence

Jinjing He iD, Rodrigo Pinheiro de Lacerda, Alberto Palella Gómez, Sally Griffin, Kinley Smith, Samuela Mazzucchelli

Veterinary Record · 2026

DOI: 10.1002/vetr.6028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Record, 2026. Verfasst von Jinjing He und 5 weiteren Autor:innen. Beteiligte Einrichtung: Willows Veterinary Centre & Referral Service, Solihull, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Eye. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aimed to characterise the normal magnetic resonance imaging (MRI) appearance of the feline eye and establish reference ranges.

Methods

Medical records of cats that underwent MRI of the head between 2022 and 2023 were reviewed. Patients with any ocular and/or orbital abnormalities were excluded. Measurements were performed from the T1‐weighted volumetric sequence.

Results

Forty‐six cats (89 eyes) were included, with a mean age at presentation of 7.5 years. Domestic shorthair was overrepresented (82%). Median axial globe length was 2.13 cm and median equatorial globe width was 2.01 cm. Median anterior chamber depth and mean vitreous chamber depth were 0.47 and 0.79 cm (±0.05 cm), respectively. Median axial lens length was 0.86 cm and median equatorial lens width was 1.33 cm. The median width of the optic nerve was 0.16 cm and the mean width of the entire optic nerve sheath was 0.45 cm (±0.05 cm). Weak positive relationships were statistically noted between skull width and axial globe length, equatorial globe width and anterior chamber depth. No associations were found between all parameters and age, weight or sex.

Limitations

Main limitations include retrospective nature, single observer and overrepresentation of domestic shorthair cats.

Conclusion

This study establishes normative values of feline ocular structures on T1‐weighted volumetric MRI sequence. Some measurements of globe dimensions vary with skull size.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingEyeAnimalsCatsFemaleMaleReference ValuesRetrospective Studies

Autor:innen und Institutionen

  • Willows Veterinary Centre & Referral Service, Solihull, UK.

ORCID-Profile: Jinjing He

Zitieren

APA

He, J., de Lacerda, R. P., Gómez, A. P., Griffin, S., Smith, K., & Mazzucchelli, S. (2026). Magnetic resonance imaging of the normal feline eye using a T1‐weighted volumetric sequence. Veterinary Record. https://doi.org/10.1002/vetr.6028

Vancouver

He J, de Lacerda RP, Gómez AP, Griffin S, Smith K, Mazzucchelli S. Magnetic resonance imaging of the normal feline eye using a T1‐weighted volumetric sequence. Veterinary Record. 2026. doi:10.1002/vetr.6028

BibTeX
@article{He2026,
  author = {He, Jinjing and de Lacerda, Rodrigo Pinheiro and Gómez, Alberto Palella and Griffin, Sally and Smith, Kinley and Mazzucchelli, Samuela},
  title = {Magnetic resonance imaging of the normal feline eye using a T1‐weighted volumetric sequence},
  journal = {Veterinary Record},
  year = {2026},
  doi = {10.1002/vetr.6028}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche