EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Comparison of the effects of an endotracheal tube and a V‐gel airway device on intraocular pressure and haemodynamic responses in anaesthetised cats

Mehmet Nur Cetin, Latif Emrah Yanmaz, Dogukan Polat, Muhammed Yusuf Sirin, Harun Cinar, Yusuf Sinan Sirin

Veterinary Record · 19.07.2025 · 197 (2)

DOI: 10.1002/vetr.5430 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Record, online erschienen am 19.05.2025. Verfasst von Mehmet Nur Cetin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University, Burdur, Turkey. Hauptthemen laut MEDLINE: Intraocular Pressure, Intubation, Intratracheal, Hemodynamics, Anesthesia. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aimed to compare the effects of placing an endotracheal tube (ETT) versus a V‐gel airway device on intraocular pressure (IOP), heart rate (HR), mean arterial pressure (MAP) and peripheral oxygen saturation (SpO 2 ) in anaesthetised cats.

Methods

Twenty animals were randomly assigned to one of two groups: the ETT group ( n = 10) or the V‐gel group ( n = 10). IOP, HR, MAP, and SpO 2 were monitored at baseline ( T b ), post‐sedation and induction ( T 0 ), immediately after intubation ( T i ), at 2 ( T 2 ), 5 ( T 5 ), 10 ( T 10 ) and 15 ( T 15 ) minutes after‐intubation, and after extubation ( T e ).

Results

IOP increased in both groups after intubation, with significantly higher values in the V‐gel group at T 2 and T 5 ( p = 0.005 and 0.014, respectively). IOP decreased below baseline by T 10 and T 15 , with no significant differences between the two groups. HR was significantly higher in the V‐gel group at T i , T 2 , T 5 and T 10 ( p = 0.001, 0.001, 0.001 and 0.016, respectively). No significant differences were observed in SpO 2 or MAP between the groups at any time point. Limitation The anaesthetic protocol may have influenced the IOP and HR, potentially confounding comparisons between the ETT and V‐gel groups.

Conclusion

The V‐gel airway device resulted in higher IOP and HR values following intubation than the ETT group. Therefore, the V‐gel may not be ideal for feline patients with ocular disease or cardiovascular compromise, where minimising IOP and cardiovascular stimulation is critical.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureIntubation, IntratrachealHemodynamicsAnesthesiaAnimalsCatsFemaleMaleHeart Rate

Stichwörter der Autor:innen

anaesthesiacatseyesocular surgery

Autor:innen und Institutionen

  • Department of Surgery, Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University, Burdur, Turkey.

Zitieren

APA

Cetin, M. N., Yanmaz, L. E., Polat, D., Sirin, M. Y., Cinar, H., & Sirin, Y. S. (2025). Comparison of the effects of an endotracheal tube and a V‐gel airway device on intraocular pressure and haemodynamic responses in anaesthetised cats. Veterinary Record, 197(2). https://doi.org/10.1002/vetr.5430

Vancouver

Cetin MN, Yanmaz LE, Polat D, Sirin MY, Cinar H, Sirin YS. Comparison of the effects of an endotracheal tube and a V‐gel airway device on intraocular pressure and haemodynamic responses in anaesthetised cats. Veterinary Record. 2025;197(2). doi:10.1002/vetr.5430

BibTeX
@article{Cetin2025,
  author = {Cetin, Mehmet Nur and Yanmaz, Latif Emrah and Polat, Dogukan and Sirin, Muhammed Yusuf and Cinar, Harun and Sirin, Yusuf Sinan},
  title = {Comparison of the effects of an endotracheal tube and a V‐gel airway device on intraocular pressure and haemodynamic responses in anaesthetised cats},
  journal = {Veterinary Record},
  year = {2025},
  volume = {197},
  number = {2},
  doi = {10.1002/vetr.5430}
}
Kostenlos starten →