Steam sterilisation of disposable surgical gowns does not compromise resistance to wet microbial penetration
Veterinary Record · 21.06.2025 · 196 (12)
DOI: 10.1002/vetr.5121 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Record, online erschienen am 28.01.2025. Verfasst von Janne Stael und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Anesthesia and Orthopedics of Large Animals, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium. Hauptthemen laut MEDLINE: Sterilization, Steam, Disposable Equipment, Surgical Attire. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Background
Reuse of disposable medical products is common practice in veterinary medicine; however, studies on the safety of such reuse are often lacking. This study aimed to determine whether steam sterilisation of disposable surgical gowns compromises their resistance to wet microbial penetration.
Methods
Twenty surgical gowns were removed from their sterile packaging, manipulated, wetted, dried and subsequently repacked and steam sterilised. The protocol was performed once (groups A and C) or twice (groups B and D) for both spunbond/meltblown/meltblown/meltblown/spunbond (SMMMS) (groups A and B) and spunlace (groups C and D) fabric types. Wet microbial penetration tests, carried out according to the European Standard EN ISO 22610, were performed and the barrier index ( I B ) was calculated to assess the performance requirements.
Results
The mean I B of the SMMMS fabric (groups A and B) and the spunlace fabric (groups C and D) were 3.496, 3.182, 3.206 and 3.490, respectively. The mean I B for all groups was significantly greater than 2.8 (group A: p = 0.005; groups B, C and D: p < 0.001).
Limitations
This was an experimental study with a small sample size, and only one of nine performance requirements specified in the relevant European standards was tested. Furthermore, no cleaning process was implemented, so the test results cannot be directly extrapolated to real‐world clinical settings.
Conclusion
In terms of wet microbial penetration, as defined by European standards, disposable surgical gowns made of SMMMS or spunlace can be safely steam sterilised up to two times.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Surgery, Anesthesia and Orthopedics of Large Animals, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
- Anicura Haaglanden, Rijswijk, The Netherlands.
ORCID-Profile: Janne Stael, Maarten Haspeslagh
Zitieren
APA
Stael, J., Haspeslagh, M., Beekhuis, I., & Martens, A. (2025). Steam sterilisation of disposable surgical gowns does not compromise resistance to wet microbial penetration. Veterinary Record, 196(12). https://doi.org/10.1002/vetr.5121
Vancouver
Stael J, Haspeslagh M, Beekhuis I, Martens A. Steam sterilisation of disposable surgical gowns does not compromise resistance to wet microbial penetration. Veterinary Record. 2025;196(12). doi:10.1002/vetr.5121
BibTeX
@article{Stael2025,
author = {Stael, Janne and Haspeslagh, Maarten and Beekhuis, Ilse and Martens, Ann},
title = {Steam sterilisation of disposable surgical gowns does not compromise resistance to wet microbial penetration},
journal = {Veterinary Record},
year = {2025},
volume = {196},
number = {12},
doi = {10.1002/vetr.5121}
}
EUVIMED