EUVIMEDEUVIMED entdecken
Crossref

Temporoorbital pulse rate can be obtained in ball pythons ( Python regius ) of any size and age and agrees with heart rate

Mio Ito, Alexander A Levitskiy iD, Nicola Di Girolamo iD

Veterinary Record · 19.10.2024 · 195 (8)

DOI: 10.1002/vetr.4596 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Record, online erschienen am 04.09.2024. Verfasst von Mio Ito und 2 weiteren Autor:innen. Beteiligte Einrichtung: Exotic Pets Service, Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA. Hauptthemen laut MEDLINE: Boidae, Heart Rate. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Currently, a standardised technique to obtain pulse rate in reptiles is lacking. We evaluated the feasibility of obtaining a temporoorbital pulse rate in ball pythons of various ages and sizes and whether it agreed with the heart rate.

Methods

Heart rate and pulse rate were recorded in 40 ball pythons ( Python regius ) weighing between 0.05 and 2.2 kg using a standard veterinary ultrasonic Doppler flow detector. The temporoorbital pulse rate was obtained on the dorsal aspect of the head at the level of the temporoorbital artery. Each measurement was performed in a randomised fashion by two operators, who were blinded to each other's results.

Results

Pulse rate and heart rate were successfully obtained for all snakes. The median heart rate was 60 beats per minute (bpm) (range 48‒88 bpm), and the median pulse rate was 60 bpm (range 48‒88 bpm). The mean difference between the pulse rate and heart rate was 1.2 beats (95% limits of agreement: ‒10.6 to 13.0). When pulse rate and heart rate were measured at the same time, they were synchronous.

Limitations

Only healthy snakes were included.

Conclusions

Temporoorbital pulse rates can be easily obtained in ball pythons of any size. This novel method to assess peripheral pulse allows for a more complete cardiovascular evaluation in this species.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BoidaeHeart RateAnimalsFemaleMalePulseBody SizeFeasibility Studies

Autor:innen und Institutionen

  • Exotic Pets Service, Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA.

ORCID-Profile: Alexander A Levitskiy, Nicola Di Girolamo

Zitieren

APA

Ito, M., Levitskiy, A. A., & Di Girolamo, N. (2024). Temporoorbital pulse rate can be obtained in ball pythons ( Python regius ) of any size and age and agrees with heart rate. Veterinary Record, 195(8). https://doi.org/10.1002/vetr.4596

Vancouver

Ito M, Levitskiy AA, Di Girolamo N. Temporoorbital pulse rate can be obtained in ball pythons ( Python regius ) of any size and age and agrees with heart rate. Veterinary Record. 2024;195(8). doi:10.1002/vetr.4596

BibTeX
@article{Ito2024,
  author = {Ito, Mio and Levitskiy, Alexander A and Di Girolamo, Nicola},
  title = {Temporoorbital pulse rate can be obtained in ball pythons ( Python regius ) of any size and age and agrees with heart rate},
  journal = {Veterinary Record},
  year = {2024},
  volume = {195},
  number = {8},
  doi = {10.1002/vetr.4596}
}
Kostenlos starten →