Accuracy and inter‐rater agreement among practitioners using quick thoracic ultrasonography to diagnose calf pneumonia
Veterinary Record · 30.03.2024 · 194 (7)
DOI: 10.1002/vetr.3896 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Record, online erschienen am 11.02.2024. Verfasst von Stan Jourquin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium. Hauptthemen laut MEDLINE: Pneumonia, Cattle Diseases. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Flanders Innovation and Entrepreneurship (VLAIO).
Abstract (Originalsprache)
Background
Thoracic ultrasonography (TUS) is a commonly used tool for on‐farm detection of pneumonia in calves. Different scanning methods have been described, but the performance of novice practitioners after training has not been documented.
Methods
In this study, 38 practitioners performed quick TUS (qTUS) on 18–23 calves each. Pneumonia was defined as lung consolidation 1 cm or more in depth. Diagnostic parameters (accuracy [Acc], sensitivity [Se] and specificity [Sp]) were compared to those of an experienced operator. Cohen's kappa and Krippendorff's alpha (Kalpha) were determined. The potential effects of training and exam sessions on performance were evaluated.
Results
The average relative Se and Sp were 0.66 (standard deviation [SD] = 0.26; minimum [Min.]–Maximum [Max.] = 0–1) and 0.71 (SD = 0.19; Min.–Max. = 0.25–1), respectively. The average relative Acc was 0.73 (SD = 0.11; Min.–Max. = 0.52–0.96). Over all sessions, Cohen's kappa averaged 0.40 (SD = 0.24; Min.–Max. = 0.014–0.90) and Kalpha was 0.24 (95% confidence interval [CI]: 0.20–0.27), indicating ‘fair’ agreement. Calf age and housing influenced Se and Sp. Supervised practical training improved Se by 17.5% (95% CI: 0.01–0.34).
Limitations
The separate effects of calf age and housing could not be determined.
Conclusion
This study showed that qTUS, like any other clinical skill, has a learning curve, and variability in performance can be substantial. Adequate training and certification of one's skill are recommended to assure good diagnostic accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
ORCID-Profile: Stan Jourquin, Thomas Lowie, Jade Bokma, Bart Pardon
Förderung
- Flanders Innovation and Entrepreneurship (VLAIO)
Zitieren
APA
Jourquin, S., Lowie, T., Bokma, J., & Pardon, B. (2024). Accuracy and inter‐rater agreement among practitioners using quick thoracic ultrasonography to diagnose calf pneumonia. Veterinary Record, 194(7). https://doi.org/10.1002/vetr.3896
Vancouver
Jourquin S, Lowie T, Bokma J, Pardon B. Accuracy and inter‐rater agreement among practitioners using quick thoracic ultrasonography to diagnose calf pneumonia. Veterinary Record. 2024;194(7). doi:10.1002/vetr.3896
BibTeX
@article{Jourquin2024,
author = {Jourquin, Stan and Lowie, Thomas and Bokma, Jade and Pardon, Bart},
title = {Accuracy and inter‐rater agreement among practitioners using quick thoracic ultrasonography to diagnose calf pneumonia},
journal = {Veterinary Record},
year = {2024},
volume = {194},
number = {7},
doi = {10.1002/vetr.3896}
}
EUVIMED