EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieOpen Access · CC BY-NC-ND 4.0

Diagnostic test accuracy of each of the four IDEA ultrasound steps in predicting presence of deep endometriosis

P McClenahan iD, J Mak iD, C Uzuner iD, M Espada Vaquero iD, S Reid, A Eathorne, G Condous, IDEA Group Collaborators

Ultrasound in Obstetrics & Gynecology · 2026-05 · 67 (5) · 679-683

DOI: 10.1002/uog.70208 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Ultrasound in Obstetrics & Gynecology, online erschienen am 01.04.2026. Verfasst von P McClenahan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Endometriosis Ultrasound and Advanced EndoSurgery Unit, Nepean Hospital, Nepean Blue Mountains Local Health District, Sydney, NSW, Australia. Hauptthemen laut MEDLINE: Endometriosis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the diagnostic performance of each additional step of the four‐step International Deep Endometriosis Analysis (IDEA) consensus protocol for predicting the presence of deep endometriosis (DE) on transvaginal ultrasound.

Methods

This was an international multicenter observational cohort study of data collected prospectively between August 2018 and November 2019, with analysis performed retrospectively. Individuals with symptoms and/or signs suggestive of endometriosis were recruited from tertiary gynecological services, underwent pelvic transvaginal ultrasound assessment according to the IDEA consensus protocol and underwent laparoscopy for excision of endometriosis. Sensitivity, specificity, accuracy, positive (PPV) and negative (NPV) predictive values, and positive (LR+) and negative (LR−) likelihood ratios for individual and cumulative steps of the IDEA protocol in diagnosing DE were calculated with corresponding 95% CIs. Visual diagnosis at laparoscopy was used as the reference standard.

Results

In total, 640 participants were recruited, of whom 467 were included in the analysis. With the addition of each step of the four‐step IDEA consensus protocol, the cumulative sensitivity for diagnosing DE increased progressively, from 0.65 (95% CI, 0.59–0.71) for Step 1 only to 0.94 (95% CI, 0.90–0.97) for Steps 1–4, the specificity decreased from 0.78 (95% CI, 0.72–0.84) to 0.58 (95% CI, 0.52–0.65), the accuracy increased from 0.71 (95% CI, 0.67–0.75) to 0.78 (95% CI, 0.74–0.81), PPV decreased from 0.78 (95% CI, 0.73–0.82) to 0.73 (95% CI, 0.70–0.76), NPV increased from 0.65 (95% CI, 0.61–0.69) to 0.89 (95% CI, 0.83–0.92), LR+ decreased from 3.02 (95% CI, 2.30–3.69) to 2.27 (95% CI, 1.93–2.67) and LR− decreased from 0.44 (95% CI, 0.37–0.53) to 0.10 (95% CI, 0.06–0.17).

Conclusions

This validation study supports the use of the comprehensive four‐step IDEA consensus protocol in detecting DE and justifies referral for specialist imaging in cases of suspected endometriosis. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EndometriosisHumansFemaleUltrasonographySensitivity and SpecificityPredictive Value of TestsAdultRetrospective StudiesLaparoscopy

Stichwörter der Autor:innen

IDEAdiagnosisendometriosisultrasound

Autor:innen und Institutionen

  • Endometriosis Ultrasound and Advanced EndoSurgery Unit, Nepean Hospital, Nepean Blue Mountains Local Health District, Sydney, NSW, Australia.
  • School of Medicine, University of Sydney, Sydney, NSW, Australia.
  • Western Sydney University, School of Medicine, Sydney, NSW, Australia.
  • Sonacare Women's Health and Ultrasound, Sydney, NSW, Australia.
  • Medical Research Institute of New Zealand, Wellington, New Zealand.

ORCID-Profile: P McClenahan, J Mak, C Uzuner, M Espada Vaquero

Zitieren

APA

McClenahan, P., Mak, J., Uzuner, C., Espada Vaquero, M., Reid, S., Eathorne, A., Condous, G., & IDEA Group Collaborators (2026). Diagnostic test accuracy of each of the four IDEA ultrasound steps in predicting presence of deep endometriosis. Ultrasound in Obstetrics & Gynecology, 67(5), 679-683. https://doi.org/10.1002/uog.70208

Vancouver

McClenahan P, Mak J, Uzuner C, Espada Vaquero M, Reid S, Eathorne A, et al. Diagnostic test accuracy of each of the four IDEA ultrasound steps in predicting presence of deep endometriosis. Ultrasound in Obstetrics & Gynecology. 2026;67(5):679-683. doi:10.1002/uog.70208

BibTeX
@article{McClenahan2026,
  author = {McClenahan, P and Mak, J and Uzuner, C and Espada Vaquero, M and Reid, S and Eathorne, A and Condous, G and IDEA Group Collaborators, IDEA Group Collaborators},
  title = {Diagnostic test accuracy of each of the four IDEA ultrasound steps in predicting presence of deep endometriosis},
  journal = {Ultrasound in Obstetrics & Gynecology},
  year = {2026},
  volume = {67},
  number = {5},
  pages = {679--683},
  doi = {10.1002/uog.70208}
}
Kostenlos starten →