Role of predelivery fetal echocardiography, cardiac magnetic resonance imaging and acute maternal hyperoxygenation in predicting urgency of neonatal balloon atrial septostomy in fetal dextro‐transposition of the great arteries
Ultrasound in Obstetrics & Gynecology · 2026
DOI: 10.1002/uog.70200 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasound in Obstetrics & Gynecology, 2026. Verfasst von E Jaeggi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Transposition of Great Vessels, Magnetic Resonance Imaging, Ultrasonography, Prenatal, Echocardiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Thrasher Research Fund, CIHR, Canadian Institutes of Health Research.
Abstract (Originalsprache)
Objective
Newborns with dextro‐transposition of the great arteries (TGA) without adequate intracardiac shunting of oxygenated blood are at imminent risk of severe hypoxia at birth. Using fetal echocardiography and cardiac magnetic resonance imaging (CMR) in room air (RA) and during acute maternal hyperoxygenation (AMH), we sought to identify predelivery imaging features predictive of neonatal hypoxia and the need for urgent balloon atrial septostomy (BAS) within the first 3 h after birth.
Methods
This was a prospective single‐center cohort study of pregnancies with TGA with an intact ventricular septum (IVS) or a single ventricular septal defect (VSD) ≤ 4 mm. Fetal echocardiography and, if feasible, CMR were conducted concurrently at 34–38 weeks' gestation. Cardiac structures, including the foramen ovale (FO) and atrial septum, were examined using two‐dimensional and Doppler echocardiography. CMR was used to quantify fetal weight, brain volume and vascular oxygen saturation (SaO 2 ). Both imaging modalities were used to assess fetal vascular blood flows in RA and during AMH. Postnatal data collected included preductal oxygen saturation (SpO 2 ) and the need for and timing of BAS. Univariable logistic regression analysis was used to evaluate associations between predelivery imaging features and the need for urgent neonatal BAS.
Results
Of 34 newborns with TGA/IVS ( n = 29) or TGA/VSD ( n = 5), 23 (68%) underwent neonatal BAS, including 12 cases of urgent BAS < 3 h after birth for persistent preductal SpO 2 < 70%. A fetal echocardiogram was obtained in all cases, while 26/34 (76%) underwent CMR, including 9/12 (75%) cases that underwent urgent BAS. On univariable logistic regression analysis, abnormal atrial septal flap morphology in RA ( P = 0.004), effective FO size ≤ 3.4 mm during AMH ( P = 0.0024) and constricted or continuously reversed diastolic flow across the ductus arteriosus (DA) during AMH ( P = 0.0006) were the most significant predictors of urgent neonatal BAS. On CMR, fetuses with an ascending aorta (AAo)/main pulmonary artery (MPA) SaO 2 ratio > 1 during AMH were significantly more likely to undergo urgent BAS postnatally (odds ratio, 28.6 (95% CI, 1.1–620.3); P = 0.0084).
Conclusion
In fetuses with TGA, predelivery assessment of atrial septal morphology in RA, as well as effective FO size, DA flow pattern and AAo/MPA SaO 2 ratio > 1 during AMH, are the most useful variables for predicting the need for urgent neonatal BAS. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada.
- Translational Medicine Research Program, SickKids Research Institute, University of Toronto, Toronto, ON, Canada.
- Ted Rogers Centre for Heart Research, University Health Network, University of Toronto, Toronto, ON, Canada.
Förderung
- Thrasher Research Fund
- CIHR
- Canadian Institutes of Health Research
Zitieren
APA
Jaeggi, E., Sun, L., Saito, M., Szabo, A., Arbic, N., Mueller, B., & Seed, M. (2026). Role of predelivery fetal echocardiography, cardiac magnetic resonance imaging and acute maternal hyperoxygenation in predicting urgency of neonatal balloon atrial septostomy in fetal dextro‐transposition of the great arteries. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.70200
Vancouver
Jaeggi E, Sun L, Saito M, Szabo A, Arbic N, Mueller B, et al. Role of predelivery fetal echocardiography, cardiac magnetic resonance imaging and acute maternal hyperoxygenation in predicting urgency of neonatal balloon atrial septostomy in fetal dextro‐transposition of the great arteries. Ultrasound in Obstetrics & Gynecology. 2026. doi:10.1002/uog.70200
BibTeX
@article{Jaeggi2026,
author = {Jaeggi, E and Sun, L and Saito, M and Szabo, A and Arbic, N and Mueller, B and Seed, M},
title = {Role of predelivery fetal echocardiography, cardiac magnetic resonance imaging and acute maternal hyperoxygenation in predicting urgency of neonatal balloon atrial septostomy in fetal dextro‐transposition of the great arteries},
journal = {Ultrasound in Obstetrics & Gynecology},
year = {2026},
doi = {10.1002/uog.70200}
}
EUVIMED