Role of maternal hyperoxygenation in predicting need for postnatal balloon atrial septostomy in fetal d‐transposition of the great arteries
Ultrasound in Obstetrics & Gynecology · 2024
DOI: 10.1002/uog.27664 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasound in Obstetrics & Gynecology, 2024. Verfasst von A Szwast und 3 weiteren Autor:innen. Beteiligte Einrichtung: Fetal Heart Program, Division of Pediatric Cardiology, Children's Hospital of Philadelphia and University of Pennsylvania School of Medicine, Philade…. Hauptthemen laut MEDLINE: Transposition of Great Vessels, Ultrasonography, Prenatal. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
Objective
Predicting whether postnatal balloon atrial septostomy (BAS) will be necessary for fetuses with dextro‐transposition of the great arteries (d‐TGA) remains challenging. We sought to determine whether fetal echocardiographic measurements obtained during maternal hyperoxygenation (MH) can improve our ability to predict the need for postnatal BAS.
Methods
This was a retrospective, single‐institution review of d‐TGA fetuses whose mothers had undergone MH at 33–38 weeks' gestation at the Children's Hospital of Philadelphia, between 1 January 2017 and 30 March 2020. All fetal d‐TGA cases had either an intact ventricular septum or small ventricular septal defect measuring < 3 mm. Patent foramen ovale (PFO) size, measured by two‐dimensional imaging (2D) and by color Doppler, and patent ductus arteriosus (PDA) shunting (antegrade vs bidirectional) were assessed in room air (RA) and during MH. BAS status and timing were recorded.
Results
Of 41 fetal d‐TGA cases in the cohort, 23 underwent postnatal BAS, while 18 did not, and 14 subjects underwent emergent BAS within 3 h of delivery. On univariate analysis, PFO size measured both in RA and during MH and antegrade shunting in the PDA during MH predicted BAS. During MH, median PFO size by 2D was significantly smaller in fetuses which underwent emergent BAS compared to fetuses which did not undergo BAS (2.5 (interquartile range (IQR), 2.0–3.0) mm vs 4.1 (IQR, 3.4–5.0) mm; P < 0.001). On cut‐point analysis, PFO size by 2D during MH of ≤ 3.2 mm predicted the need for emergent BAS with a sensitivity of 93% (95% CI, 66–100%) and a specificity of 78% (95% CI, 58–91%).
Conclusions
In fetuses with d‐TGA, measurement of PFO size and direction of PDA shunting during MH improves our ability to predict the need for postnatal BAS, although additional study is needed. We propose incorporating third‐trimester MH when planning delivery of a d‐TGA fetus. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Fetal Heart Program, Division of Pediatric Cardiology, Children's Hospital of Philadelphia and University of Pennsylvania School of Medicine, Philadelphia, PA, USA.
- Data Science and Biostatistics Unit, Children's Hospital of Philadelphia, Philadelphia, PA, USA.
ORCID-Profile: A Szwast
Zitieren
APA
Szwast, A., Penney, C., Sharma, P., & Rychik, J. (2024). Role of maternal hyperoxygenation in predicting need for postnatal balloon atrial septostomy in fetal d‐transposition of the great arteries. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.27664
Vancouver
Szwast A, Penney C, Sharma P, Rychik J. Role of maternal hyperoxygenation in predicting need for postnatal balloon atrial septostomy in fetal d‐transposition of the great arteries. Ultrasound in Obstetrics & Gynecology. 2024. doi:10.1002/uog.27664
BibTeX
@article{Szwast2024,
author = {Szwast, A and Penney, C and Sharma, P and Rychik, J},
title = {Role of maternal hyperoxygenation in predicting need for postnatal balloon atrial septostomy in fetal d‐transposition of the great arteries},
journal = {Ultrasound in Obstetrics & Gynecology},
year = {2024},
doi = {10.1002/uog.27664}
}
EUVIMED