Measuring quality of reporting in systematic reviews of diagnostic test accuracy studies in medical imaging: comparison of PRISMA‐DTA and PRISMA
Ultrasound in Obstetrics & Gynecology · 2023
DOI: 10.1002/uog.26043 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasound in Obstetrics & Gynecology, 2023. Verfasst von Q Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, West China Hospital, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Checklist, Diagnostic Tests, Routine, Systematic Reviews as Topic. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation, Ministry of Science and Technology of the People's Republic of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Objectives
To compare the reporting quality measured by the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses of Diagnostic Test Accuracy studies (PRISMA‐DTA) vs the original PRISMA checklist for systematic reviews of diagnostic test accuracy studies in imaging and survey the use of PRISMA‐DTA by researchers and endorsement by journals.
Methods
Systematic reviews of DTA studies published in 2020 and 2021 in Quartile 1 and Quartile 3 medical imaging journals (defined by Journal Citation Reports) were identified through PubMed. The reporting of each systematic review was assessed using PRISMA‐DTA, PRISMA‐2009 and PRISMA‐2020. The item scores and overall score were compared among the three checklists. We also examined checklist adoption by the included systematic reviews and surveyed checklist endorsement from author instructions of included journals.
Results
A total of 173 systematic reviews from 66 journals were included. The use of PRISMA‐DTA, compared with PRISMA‐2009 and PRISMA‐2020, identified more issues in the reporting of title (proportion of systematic reviews with proper reporting, 27.2% vs 98.8% vs 98.8%), abstract (39.3% vs 97.1% vs 64.7%), eligibility criteria (67.6% vs 94.2% vs 94.2%), search (28.9% vs 72.3% vs 28.9%), definitions for data extraction (14.5% vs 91.9% vs 91.9%), diagnostic accuracy measures (38.2% vs 93.6% vs 93.6%), synthesis of results (28.9% vs 89.6% vs 73.4%) and results of individual studies (40.5% vs 80.3% vs 80.3%). The overall median reporting score measured by PRISMA‐DTA (72.0% (interquartile range (IQR), 66.7–77.8%)) was lower than that measured by PRISMA‐2009 (88.9% (IQR, 84.0–92.6%)) and similar to that measured by PRISMA‐2020 (74.1% (IQR, 66.7–77.8%)). Additionally, PRISMA‐DTA was used by only 43 (24.9%) systematic reviews and endorsed by two (3.0%) journals. These trends remained consistent for reviews published in journals with diverse scientific impact.
Conclusions
The use of PRISMA‐DTA may identify more reporting inadequacies compared with the original PRISMA checklists when assessing diagnostic test accuracy systematic reviews, especially in critical sections such as title, abstract and methods. However, this tool is not commonly used by researchers and is inadequately endorsed by imaging journals. Our findings suggest a strong need to use PRISMA‐DTA for reporting of diagnostic test accuracy systematic reviews by authors and its endorsement by journals. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nuclear Medicine, West China Hospital, Sichuan University, Chengdu, China.
- Chinese Evidence-Based Medicine Center, Cochrane China Center and MAGIC China Center, West China Hospital, Sichuan University, Chengdu, China.
- NMPA Key Laboratory for Real World Data Research and Evaluation in Hainan, Chengdu, China.
- Sichuan Center of Technology Innovation for Real World Data, Chengdu, Sichuan, China.
ORCID-Profile: Q Li
Förderung
- China Postdoctoral Science Foundation
- Ministry of Science and Technology of the People's Republic of China
- National Natural Science Foundation of China
- West China Hospital, Sichuan University
Zitieren
APA
Li, Q., Hou, W., Li, L., Xu, J., Ren, Y., Zou, K., Tian, R., & Sun, X. (2023). Measuring quality of reporting in systematic reviews of diagnostic test accuracy studies in medical imaging: comparison of PRISMA‐DTA and PRISMA. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.26043
Vancouver
Li Q, Hou W, Li L, Xu J, Ren Y, Zou K, et al. Measuring quality of reporting in systematic reviews of diagnostic test accuracy studies in medical imaging: comparison of PRISMA‐DTA and PRISMA. Ultrasound in Obstetrics & Gynecology. 2023. doi:10.1002/uog.26043
BibTeX
@article{Li2023,
author = {Li, Q and Hou, W and Li, L and Xu, J and Ren, Y and Zou, K and Tian, R and Sun, X},
title = {Measuring quality of reporting in systematic reviews of diagnostic test accuracy studies in medical imaging: comparison of PRISMA‐DTA and PRISMA},
journal = {Ultrasound in Obstetrics & Gynecology},
year = {2023},
doi = {10.1002/uog.26043}
}
EUVIMED