EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Role of fetal head‐circumference‐to‐maternal‐height ratio in predicting Cesarean section for labor dystocia: prospective multicenter study

A Dall'Asta iD, R Ramirez Zegarra iD, E Corno, I Mappa, J L A Lu iD, E Di Pasquo iD, G Morganelli, M Abou-Dakn, C Germano, R Attini, B Masturzo, G Rizzo iD und 1 weitere

Ultrasound in Obstetrics & Gynecology · 2023-01 · 61 (1) · 93-98

DOI: 10.1002/uog.24981 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Ultrasound in Obstetrics & Gynecology, online erschienen am 03.01.2023. Verfasst von A Dall'Asta und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy. Hauptthemen laut MEDLINE: Dystocia, Labor, Obstetric. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the relationship between the fetal head‐circumference‐to‐maternal‐height (HC/MH) ratio measured shortly before delivery and the occurrence of Cesarean section (CS) for labor dystocia.

Methods

This was a multicenter prospective cohort study involving four tertiary maternity hospitals. An unselected cohort of women with a singleton fetus in cephalic presentation, at a gestational age beyond 36 + 0 weeks and without any contraindication for vaginal delivery, was enrolled between September 2020 and November 2021. The MH and fetal HC were measured on admission of the patient to the labor ward. The primary outcome of the study was the performance of the HC/MH ratio in the prediction of CS for labor dystocia. Women who underwent CS for any indication other than failed labor progression, including fetal distress, were excluded from the final analysis.

Results

A total of 783 women were included in the study. Vaginal delivery occurred in 744 (95.0%) women and CS for labor dystocia in 39 (5.0%). CS for labor dystocia was associated with shorter MH (mean ± SD, 160.4 ± 6.6 vs 164.5 ± 6.3 cm; P < 0.001), larger fetal HC (339.6 ± 9.5 vs 330.7 ± 13.0 mm; P < 0.001) and a higher HC/MH ratio (2.12 ± 0.11 vs 2.01 ± 0.10; P < 0.001) compared with vaginal delivery. Multivariate logistic regression analysis showed that the HC/MH ratio was associated independently with CS for labor dystocia (adjusted odds ratio, 2.65 (95% CI, 1.85–3.79); P < 0.001). The HC/MH ratio had an area under the receiver‐operating‐characteristics curve of 0.77 and an optimal cut‐off value for discriminating between vaginal delivery and CS for labor dystocia of 2.09, which was associated with a sensitivity of 0.62 (95% CI, 0.45–0.77), specificity of 0.79 (95% CI, 0.76–0.82), positive predictive value of 0.13 (95% CI, 0.09–0.19) and negative predictive value of 0.98 (95% CI, 0.96–0.99).

Conclusions

In a large cohort of unselected pregnancies, the HC/MH ratio performed better than did fetal HC and MH alone in identifying those cases that will undergo CS for labor dystocia, albeit with moderate predictive value. The HC/MH ratio could assist in the evaluation of women at risk for CS for labor dystocia. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DystociaLabor, ObstetricPregnancyFemaleHumansInfantMaleCesarean SectionProspective StudiesUltrasonography, Prenatal

Stichwörter der Autor:innen

Cesarean sectionhead circumferencelabor dystociamaternal heightvaginal delivery

Autor:innen und Institutionen

  • Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.
  • Department of Obstetrics and Gynecology, St Joseph Krankenhaus, Berlin, Germany.
  • Department of Obstetrics and Gynecology, Fondazione Policlinico Tor Vergata, University of Rome Tor Vergata, Rome, Italy.
  • Department of Obstetrics and Gynecology, Sant'Anna Hospital, University of Turin, Turin, Italy.

ORCID-Profile: A Dall'Asta, R Ramirez Zegarra, J L A Lu, E Di Pasquo, G Rizzo, T Ghi

Zitieren

APA

Dall'Asta, A., Ramirez Zegarra, R., Corno, E., Mappa, I., Lu, J. L. A., Di Pasquo, E., Morganelli, G., Abou-Dakn, M., Germano, C., Attini, R., Masturzo, B., Rizzo, G., & Ghi, T. (2023). Role of fetal head‐circumference‐to‐maternal‐height ratio in predicting Cesarean section for labor dystocia: prospective multicenter study. Ultrasound in Obstetrics & Gynecology, 61(1), 93-98. https://doi.org/10.1002/uog.24981

Vancouver

Dall'Asta A, Ramirez Zegarra R, Corno E, Mappa I, Lu JLA, Di Pasquo E, et al. Role of fetal head‐circumference‐to‐maternal‐height ratio in predicting Cesarean section for labor dystocia: prospective multicenter study. Ultrasound in Obstetrics & Gynecology. 2023;61(1):93-98. doi:10.1002/uog.24981

BibTeX
@article{DallAsta2023,
  author = {Dall'Asta, A and Ramirez Zegarra, R and Corno, E and Mappa, I and Lu, J L A and Di Pasquo, E and Morganelli, G and Abou-Dakn, M and Germano, C and Attini, R and Masturzo, B and Rizzo, G and Ghi, T},
  title = {Role of fetal head‐circumference‐to‐maternal‐height ratio in predicting Cesarean section for labor dystocia: prospective multicenter study},
  journal = {Ultrasound in Obstetrics & Gynecology},
  year = {2023},
  volume = {61},
  number = {1},
  pages = {93--98},
  doi = {10.1002/uog.24981}
}
Kostenlos starten →