The Learning Curve of Junior Endoscopists in EUS‐Guided Gastroenterostomy With the Wireless Simplified Technique: A Prospective Study
United European Gastroenterology Journal · 2026
DOI: 10.1002/ueg2.70170 ↗Kurz gefasst
Fachartikel in der Zeitschrift United European Gastroenterology Journal, 2026. Verfasst von Giuseppe Vanella und 14 weiteren Autor:innen. Beteiligte Einrichtung: Pancreatobiliary Endoscopy and Endosonography Division, IRCCS San Raffaele Scientific Institute, Milan, Italy. Hauptthemen laut MEDLINE: Learning Curve, Endosonography, Gastroenterostomy, Gastric Outlet Obstruction. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministry of Health with Ricerca Corrente, Ministero dell’Istruzione, dell’Università e della Ricerca.
Abstract (Originalsprache)
Introduction
Learning curve of EUS‐guided Gastroenterostomy (EUS‐GE) has been explored through retrospective studies involving few elite senior endoscopists (SE), with procedural time as the main surrogate outcome. This study aims to evaluate the training of junior endoscopists (JE) approaching the technique and cover clinically relevant patient outcomes.
Methods
From a prospective single‐center registry (PROTECT, ClinicalTrials.gov NCT04813055) of EUS‐GE for malignant Gastric Outlet Obstruction using the Wireless Simplified [WEST] technique, the learning curve of 3 JE experienced in pancreatobiliary endoscopy was analyzed to identify changing points (“knots”) applying linear and spline regression and cumulative sum control chart (CUSUM) on several continuous and dichotomic variables. EUS‐GE performed by a SE and different indications were excluded.
Results
From a database of 165 EUS‐GEs, 100 were performed by one novice endoscopist with prior EUS‐GE exposure (JE1) and 35 by two naïve endoscopists (JE2/JE3). On the largest curve (JE1), procedural time and fluoroscopy time did not show any improvement. The use of fluoroscopy (median Air Kerma: 267 Gy [172–506]) showed a significant improvement after 57 interventions (spline regression) and 72 interventions (CUSUM), after which the curve stabilized. The need for supervision/backup of a SE showed a knot after 32 interventions. Technical success (99%), Clinical success (96%), Misdeployments (2%) and AEs (6%) were stable along the learning curve. Conversion from EUS‐GE to enteral stenting (11%) tended to decrease over time. Despite naïve endoscopists required significantly higher fluoroscopy time (234 vs. 187 s, p = 0.009) and procedural time (55 vs. 43 min, p = 0.002) than JE1, efficacy and safety outcomes were not different from the general cohort.
Conclusions
From a prospective registry, ≈30 EUS‐GE seems required for independent practice, and ≈55–70 to minimize and stabilize the use of fluoroscopy. Endoscopists learning EUS‐GE in high‐volume institutions using a standardized technique do not compromise high clinical and safety standards.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pancreatobiliary Endoscopy and Endosonography Division, IRCCS San Raffaele Scientific Institute, Milan, Italy.
- Vita-Salute San Raffaele University, Milan, Italy.
- University of Turin, Turin, Italy.
- Division of Epidemiology and Biostatistics, IEO, European Institute of Oncology IRCCS, Milan, Italy.
ORCID-Profile: Francesco Frigo, Francesca Perelli, Rukaia Barà, Patrick Maisonneuve, Matteo Tacelli, Niccolò Bina, Rubino Nunziata, Ruggero Ponz De Leon Pisani, Paolo Giorgio Arcidiacono
Förderung
- Ministry of Health with Ricerca Corrente
- Ministero dell’Istruzione, dell’Università e della Ricerca
Zitieren
APA
Vanella, G., Frigo, F., Perelli, F., Barà, R., Maisonneuve, P., Archibugi, L., Tacelli, M., Lauri, G., Bellafante, D., Bina, N., Nunziata, R., Biamonte, P., Ponz De Leon Pisani, R., Capurso, G., & Arcidiacono, P. G. (2026). The Learning Curve of Junior Endoscopists in EUS‐Guided Gastroenterostomy With the Wireless Simplified Technique: A Prospective Study. United European Gastroenterology Journal. https://doi.org/10.1002/ueg2.70170
Vancouver
Vanella G, Frigo F, Perelli F, Barà R, Maisonneuve P, Archibugi L, et al. The Learning Curve of Junior Endoscopists in EUS‐Guided Gastroenterostomy With the Wireless Simplified Technique: A Prospective Study. United European Gastroenterology Journal. 2026. doi:10.1002/ueg2.70170
BibTeX
@article{Vanella2026,
author = {Vanella, Giuseppe and Frigo, Francesco and Perelli, Francesca and Barà, Rukaia and Maisonneuve, Patrick and Archibugi, Livia and Tacelli, Matteo and Lauri, Gaetano and Bellafante, Daniele and Bina, Niccolò and Nunziata, Rubino and Biamonte, Paolo and Ponz De Leon Pisani, Ruggero and Capurso, Gabriele and Arcidiacono, Paolo Giorgio},
title = {The Learning Curve of Junior Endoscopists in EUS‐Guided Gastroenterostomy With the Wireless Simplified Technique: A Prospective Study},
journal = {United European Gastroenterology Journal},
year = {2026},
doi = {10.1002/ueg2.70170}
}
EUVIMED