5G‐based remote magnetically controlled capsule endoscopy for examination of the stomach and small bowel
United European Gastroenterology Journal · 2023-02 · 11 (1) · 42-50
DOI: 10.1002/ueg2.12339 ↗Kurz gefasst
Fachartikel in der Zeitschrift United European Gastroenterology Journal, online erschienen am 23.11.2022. Verfasst von Ting Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: National Clinical Research Center for Digestive Diseases, Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, Chin…. Hauptthemen laut MEDLINE: Capsule Endoscopy, Gastrointestinal Diseases. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background and aims Remote endoscopy can improve diagnostic efficiency of gastrointestinal (GI) diseases for patients in remote areas. A novel remote magnetically controlled capsule endoscopy (MCE) system based on a 5G network was developed for real‐time remote GI examinations. We aimed to evaluate the feasibility and safety of the 5G‐based remote MCE for examination of the stomach and small bowel.
Methods
This was a prospective, nonrandomized, comparative study. Consecutive participants enrolled in the First People's Hospital of Yinchuan underwent remote MCE examinations performed by an endoscopist located in Changhai Hospital. Consecutive participants enrolled in Changhai Hospital underwent conventional MCE examinations performed by the same endoscopist. The main outcomes included the complete visualization rate of the stomach and small bowel, safety assessment and network latency time of remote MCE examinations.
Results
From March 2021 to June 2021, 20 participants in each group were enrolled. The complete visualization rate of the stomach and small bowel was 100% in both groups ( p > 0.999) without any adverse event. The median network latency time of remote MCE group was 19.948 ms. Gastric examination time (8.96 vs. 8.92 min, p = 0.234), maneuverability (15.00 vs. 15.00, p = 0.317), image quality (1.00 vs. 1.00, p > 0.999) and diagnostic yields in the stomach and small bowel (55% vs. 30%, 5% vs. 0%, both p > 0.05) were comparable between remote and conventional MCE groups. All participants in remote MCE group considered remote MCE acceptable and necessary.
Conclusions
5G‐based remote MCE was a feasible and safe method for viewing the stomach and small bowel.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Clinical Research Center for Digestive Diseases, Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.
- Department of Gastroenterology, The First People's Hospital of Yinchuan, Yinchuan, Ningxia, China.
ORCID-Profile: Zhuan Liao
Zitieren
APA
Zhang, T., Chen, Y. Z., Jiang, X., He, C., Pan, J., Zhou, W., Hu, J. P., Liao, Z., & Li, Z. S. (2023). 5G‐based remote magnetically controlled capsule endoscopy for examination of the stomach and small bowel. United European Gastroenterology Journal, 11(1), 42-50. https://doi.org/10.1002/ueg2.12339
Vancouver
Zhang T, Chen YZ, Jiang X, He C, Pan J, Zhou W, et al. 5G‐based remote magnetically controlled capsule endoscopy for examination of the stomach and small bowel. United European Gastroenterology Journal. 2023;11(1):42-50. doi:10.1002/ueg2.12339
BibTeX
@article{Zhang2023,
author = {Zhang, Ting and Chen, Yi-Zhi and Jiang, Xi and He, Chen and Pan, Jun and Zhou, Wei and Hu, Jian-Ping and Liao, Zhuan and Li, Zhao-Shen},
title = {5G‐based remote magnetically controlled capsule endoscopy for examination of the stomach and small bowel},
journal = {United European Gastroenterology Journal},
year = {2023},
volume = {11},
number = {1},
pages = {42--50},
doi = {10.1002/ueg2.12339}
}