EUVIMEDEUVIMED entdecken
Crossref

Seismic Behavior Research of IFW Assembled Shear Wall

Jia‐Xi Zhang, Jin‐Shuang Dong, Yu‐Bo Liu, Yun Chen

The Structural Design of Tall and Special Buildings · 2026-11 · 35 (11)

DOI: 10.1002/tal.70182 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Structural Design of Tall and Special Buildings, online erschienen am 16.11.2026. Verfasst von Jia‐Xi Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In view of the current challenges associated with composite shear walls, this paper innovatively integrates the advantages of both wall types. The connection structure and manufacturing process of prefabricated walls are optimized and innovated, and an integration of single‐sided formwork and single‐superimposed shear wall (hereinafter referred to as IFW) is proposed. To systematically investigate the seismic performance of IFW prefabricated shear walls, low‐cycle reversed loading tests were conducted on five large‐scale IFW shear wall specimens and two cast‐in‐place (CIP) shear wall specimens, all with a height‐to‐width ratio of 2.8. The test parameters included the axial compression ratio, the cross‐sectional area of the connection lap bars between the upper and lower prefabricated wall panels, and the presence or absence of “X”‐shaped anti‐slip components. The research demonstrates the following: The CIP and precast concrete layers in the IFW specimens bonded well and exhibited composite action. All specimens ultimately failed in flexural mode. Except for specimen IFW‐5, no significant differences were observed in the energy dissipation capacity, ductility coefficient, and stiffness degradation behavior between the standard IFW specimens (without enhancement measures) and the CIP specimens. “X”‐shaped anti‐slip components increased the energy dissipation capacity of the IFW specimens by 17.5% and the ductility coefficient by 33.5%. Increasing the cross‐sectional area of the connection lap bars effectively improved the initial stiffness, load‐bearing capacity, energy dissipation capacity, and ductility coefficient of the IFW specimens, accompanied by an upward shift of the plastic hinge. When the lap bar cross‐sectional area was increased by 51%, the load‐bearing capacity and energy dissipation capacity of the IFW specimens exceeded those of the CIP specimens. The ultimate displacement angles ranged between 1/50 and 1/31, indicating good ductility. Based on experimental validation, finite element analysis was extended to unexplored aspect ratios. The results confirmed that the proposed modeling approach accurately predicts the mechanical behavior of IFW walls. The analysis also showed that the failure mode shifts from shear to flexural failure as the aspect ratio increases. A calculation formula for the bearing capacity of IFW shear walls is proposed and validated against the test results, showing good agreement between predictions and measurements.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, J., Dong, J., Liu, Y., & Chen, Y. (2026). Seismic Behavior Research of IFW Assembled Shear Wall. The Structural Design of Tall and Special Buildings, 35(11). https://doi.org/10.1002/tal.70182

Vancouver

Zhang J, Dong J, Liu Y, Chen Y. Seismic Behavior Research of IFW Assembled Shear Wall. The Structural Design of Tall and Special Buildings. 2026;35(11). doi:10.1002/tal.70182

BibTeX
@article{Zhang2026,
  author = {Zhang, Jia‐Xi and Dong, Jin‐Shuang and Liu, Yu‐Bo and Chen, Yun},
  title = {Seismic Behavior Research of IFW Assembled Shear Wall},
  journal = {The Structural Design of Tall and Special Buildings},
  year = {2026},
  volume = {35},
  number = {11},
  doi = {10.1002/tal.70182}
}
Kostenlos starten →