Ultra‐Trace Quantification of N‐Nitroso‐Epinephrine in Epinephrine Injection by Ultra‐High‐Performance Liquid Chromatography Quadrupole Time‐of‐Flight High‐Resolution Mass Spectrometry
SEPARATION SCIENCE PLUS · 2026-11 · 9 (11)
DOI: 10.1002/sscp.70354 ↗Kurz gefasst
Fachartikel in der Zeitschrift SEPARATION SCIENCE PLUS, online erschienen am 13.11.2026. Verfasst von Ramamohana Reddy Maddike und 3 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben.
Abstract (Originalsprache)
Epinephrine injection is a life‐saving parenteral product whose acidic formulation environment creates conditions that may promote the formation of nitrosamine drug substance‐related impurities—compounds of serious toxicological concern due to their genotoxic and carcinogenic potential. This study describes the development and validation of a highly sensitive and selective ultra‐high‐performance liquid chromatography quadrupole time‐of‐flight high‐resolution mass spectrometry method for the detection and quantification of N‐nitroso‐epinephrine (NNE), a nitrosamine impurity directly derived from the epinephrine drug substance, in epinephrine injection. Structural risk assessment using the United States Food and Drug Administration Carcinogenic Potency Categorization Approach classified NNE as a Category 2 nitrosamine, establishing an acceptable intake limit of 100 ng/day and a corresponding specification limit of 100 ng/mL based on the maximum daily dose of epinephrine. Chromatographic separation was achieved on a bridged ethylene hybrid C18 column using a gradient mobile phase of formic acid‐modified water and acetonitrile. Detection was carried out in positive electrospray ionization mode, with NNE confidently identified through a precursor ion at m/z 213.08540 and a product ion at m/z 135.04485. The method delivered outstanding sensitivity, with a limit of detection of 0.3 ng/mL and a limit of quantification of 1.0 ng/mL, and demonstrated excellent linearity across 1.0–150 ng/mL. Full validation in accordance with ICH Q2(R2) and USP General Chapter 1225 confirmed satisfactory precision, accuracy, robustness, and 24‐h solution stability. Accelerated stability testing at 60°C over 15 days showed no measurable increase in NNE, indicating that the evaluated formulation does not readily promote nitrosamine formation under the stress conditions tested.
Zitieren
APA
Maddike, R. R., Nallagondu, C. G. R., Kothamasu, S. B., & Elala, P. R. (2026). Ultra‐Trace Quantification of N‐Nitroso‐Epinephrine in Epinephrine Injection by Ultra‐High‐Performance Liquid Chromatography Quadrupole Time‐of‐Flight High‐Resolution Mass Spectrometry. SEPARATION SCIENCE PLUS, 9(11). https://doi.org/10.1002/sscp.70354
Vancouver
Maddike RR, Nallagondu CGR, Kothamasu SB, Elala PR. Ultra‐Trace Quantification of N‐Nitroso‐Epinephrine in Epinephrine Injection by Ultra‐High‐Performance Liquid Chromatography Quadrupole Time‐of‐Flight High‐Resolution Mass Spectrometry. SEPARATION SCIENCE PLUS. 2026;9(11). doi:10.1002/sscp.70354
BibTeX
@article{Maddike2026,
author = {Maddike, Ramamohana Reddy and Nallagondu, Chinna Gangi Reddy and Kothamasu, Suresh Babu and Elala, Pravardhan Reddy},
title = {Ultra‐Trace Quantification of N‐Nitroso‐Epinephrine in Epinephrine Injection by Ultra‐High‐Performance Liquid Chromatography Quadrupole Time‐of‐Flight High‐Resolution Mass Spectrometry},
journal = {SEPARATION SCIENCE PLUS},
year = {2026},
volume = {9},
number = {11},
doi = {10.1002/sscp.70354}
}
EUVIMED