Fachartikel in der Zeitschrift SEPARATION SCIENCE PLUS, online erschienen am 13.11.2026. Verfasst von Maryane Maria Barros de Farias‐Ferreira und 5 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Oxidative degradation is one of the most common degradation pathways in pharmaceutical systems, second only to hydrolysis. Redox‐active pharmaceutical compounds are particularly susceptible to oxidative processes, posing significant challenges for drug stability and the development of stability‐indicating analytical methods. Clofazimine, a highly lipophilic riminophenazine derivative, represents a particular analytical challenge because of its limited aqueous solubility, pH‐dependent ionization, and redox‐active moieties, which complicate the design of forced‐degradation studies and selective degradation monitoring. This study aimed to develop and validate a stability‐indicating high‐performance liquid chromatographic method for determination of clofazimine in the presence of degradation‐related chromatographic signals using an integrated approach combining in silico prediction and high‐resolution mass spectrometry. Forced‐degradation studies were conducted under oxidative conditions using hydrogen peroxide (3%), as well as under acidic (1 mol·L − 1 hydrochloric acid) and alkaline (1 mol·L − 1 sodium hydroxide) conditions. Additional studies were performed under thermal, humidity, and photolytic stress conditions in the solid state. Chromatographic separation was achieved by gradient elution on a Zorbax Eclipse Plus C8 column (250 × 4.6 mm, 5 µm), employing a formate buffer/acetonitrile mobile phase with detection at 280 nm. The validated method demonstrated adequate linearity ( r 2 ≥ 0.997), precision (relative standard deviation < 2%), and accuracy within acceptable recovery limits. High‐resolution mass spectrometry enabled the tentative structural assessment of degradation products, supporting the predicted oxidative pathways. Overall, the method provided a selective analytical approach for monitoring clofazimine degradation under the investigated stress conditions and highlighted the applicability of integrating experimental and in silico approaches for oxidative degradation profiling.
Zitieren
APA
Farias‐Ferreira, M. M. B. D., Fernandes, J. M., Silva, A. L. E., Tavares, J. F., Soares‐Sobrinho, J. L., & Soares, M. F. D. L. R. (2026). An Integrated Analytical Strategy Combining Stability‐Indicating Liquid Chromatography, High‐Resolution Mass Spectrometry and In Silico Prediction for Oxidative Degradation Profiling of Clofazimine. SEPARATION SCIENCE PLUS, 9(11). https://doi.org/10.1002/sscp.70351
Vancouver
Farias‐Ferreira MMBD, Fernandes JM, Silva ALE, Tavares JF, Soares‐Sobrinho JL, Soares MFDLR. An Integrated Analytical Strategy Combining Stability‐Indicating Liquid Chromatography, High‐Resolution Mass Spectrometry and In Silico Prediction for Oxidative Degradation Profiling of Clofazimine. SEPARATION SCIENCE PLUS. 2026;9(11). doi:10.1002/sscp.70351
BibTeX
@article{FariasFerreira2026,
author = {Farias‐Ferreira, Maryane Maria Barros de and Fernandes, Júlia Morais and Silva, Anauara Lima e and Tavares, Josean Fechine and Soares‐Sobrinho, José Lamartine and Soares, Mônica Felts de La Roca},
title = {An Integrated Analytical Strategy Combining Stability‐Indicating Liquid Chromatography, High‐Resolution Mass Spectrometry and In Silico Prediction for Oxidative Degradation Profiling of Clofazimine},
journal = {SEPARATION SCIENCE PLUS},
year = {2026},
volume = {9},
number = {11},
doi = {10.1002/sscp.70351}
}
EUVIMED