EUVIMEDEUVIMED entdecken
Crossref

Centrifugation Assisted Two‐Phase Hollow‐Fiber Liquid‐Phase Microextraction Coupled With Direct Fluorimetry for Precise Thiamine Detection

Lianfeng Liu, Turghun Muhammad, Jia Zhao, Feiyu Zhan, Yan Zhang

SEPARATION SCIENCE PLUS · 2026-03 · 9 (3)

DOI: 10.1002/sscp.70209 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SEPARATION SCIENCE PLUS, online erschienen am 10.03.2026. Verfasst von Lianfeng Liu und 4 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the poor reproducibility associated with manual acceptor phase collection in two‐phase hollow‐fiber liquid‐phase microextraction, we introduce a novel centrifugal collection technique for the first time. Thiamine, selected as a model analyte, was oxidized into fluorescent thiochrome and extracted via hollow‐fiber liquid‐phase microextraction. Following extraction, centrifugation at 7000 rpm quantitatively transferred 15.7 ± 0.4 µL (relative standard deviation [RSD] 2.55%) of the acceptor phase, accounting for over 80% recovery, from the hollow fiber into a glass capillary for direct fluorescence detection. This procedure enhanced collection efficiency nearly 7‐fold and reduced RSD to 2.55%, compared with 2.3 ± 0.5 µL and 21.74% for the conventional syringe‐based method. Optimal extraction conditions were established as follows: n ‐heptanol as the acceptor phase, a 20 min extraction time, 400 rpm orbital shaking, 15% NaCl, and 8 min for acceptor phase loading. Under these optimal conditions, a good linear relationship was established for thiamine across the concentration range of 0.05–3.0 µg/mL ( R 2 = 0.9996), with recoveries exceeding 91.0% and a limit of detection (LOD) of 1.112 × 10 −2 µg/mL. The intra‐day and inter‐day RSD ( n = 7) were below 1.7%. The proposed centrifugal collection method is simple, highly reproducible, and efficient, offering a generic strategy to enhance reliability and throughput for the hollow‐fiber liquid‐phase microextraction technique.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Liu, L., Muhammad, T., Zhao, J., Zhan, F., & Zhang, Y. (2026). Centrifugation Assisted Two‐Phase Hollow‐Fiber Liquid‐Phase Microextraction Coupled With Direct Fluorimetry for Precise Thiamine Detection. SEPARATION SCIENCE PLUS, 9(3). https://doi.org/10.1002/sscp.70209

Vancouver

Liu L, Muhammad T, Zhao J, Zhan F, Zhang Y. Centrifugation Assisted Two‐Phase Hollow‐Fiber Liquid‐Phase Microextraction Coupled With Direct Fluorimetry for Precise Thiamine Detection. SEPARATION SCIENCE PLUS. 2026;9(3). doi:10.1002/sscp.70209

BibTeX
@article{Liu2026,
  author = {Liu, Lianfeng and Muhammad, Turghun and Zhao, Jia and Zhan, Feiyu and Zhang, Yan},
  title = {Centrifugation Assisted Two‐Phase Hollow‐Fiber Liquid‐Phase Microextraction Coupled With Direct Fluorimetry for Precise Thiamine Detection},
  journal = {SEPARATION SCIENCE PLUS},
  year = {2026},
  volume = {9},
  number = {3},
  doi = {10.1002/sscp.70209}
}
Kostenlos starten →