DOI: 10.1002/sscp.70152 ↗Kurz gefasst
Fachartikel in der Zeitschrift SEPARATION SCIENCE PLUS, online erschienen am 03.11.2025. Verfasst von Abhishek Sharma und 3 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
Clozapine is an atypical tricyclic dibenzodiazepine antipsychotic. Both clozapine and its related impurity contain secondary amine moieties that are susceptible to nitrosation, potentially leading to the formation of N‐nitroso Clozapine (N‐CZN) and N‐nitroso clozapine impurity C (N‐CZNC) during manufacturing, storage, and stability testing. This study reports the development and validation of a green and highly sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the simultaneous trace‐level quantification of N‐CZN and N‐CZNC in drug substances and pharmaceutical formulations. Chromatographic separation was achieved using an Agilent Poroshell HPH C18 column under gradient elution. Mobile phase A consisted of 0.01 M ammonium bicarbonate in water, while mobile phase B comprised 0.1% formic acid in a 50:50 (v/v) methanol: acetonitrile mixture, with a flow rate of 0.5 mL/min and column temperature maintained at 40°C. Detection was performed by electrospray ionization in multiple reaction monitoring mode, with transitions monitored at m / z 356.0 → 326.0 for N‐CZN and m / z 342.1 → 312.0 for N‐CZNC. The method was validated as per International Council for Harmonization guidelines (ICH) and United States Pharmacopeia (USP) , demonstrating excellent linearity ( R 2 > 0.999) over the range from the LOQ to 150%. The LOD and LOQ were determined to be 0.058 and 0.177 µg/mL, respectively, for N‐CZN, and 0.014 and 0.044 µg/mL respectively, for N‐CZNC. The method exhibited satisfactory accuracy, with recoveries between 88% and 102%. The validated method was successfully transferred to the quality control laboratory, where it is currently employed for the routine analysis of three batches of drug substances and finished formulations.
Zitieren
APA
Sharma, A., Pedavenkatagari, N. R., Ettaboina, S. K., & Nakka, S. (2025). A Green and Ultra‐Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Simultaneous Trace‐Level Quantification of Nitrosamine Drug Substance Related Impurities in Clozapine: Method Development, Validation, and Greenness Evaluation. SEPARATION SCIENCE PLUS, 8(11). https://doi.org/10.1002/sscp.70152
Vancouver
Sharma A, Pedavenkatagari NR, Ettaboina SK, Nakka S. A Green and Ultra‐Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Simultaneous Trace‐Level Quantification of Nitrosamine Drug Substance Related Impurities in Clozapine: Method Development, Validation, and Greenness Evaluation. SEPARATION SCIENCE PLUS. 2025;8(11). doi:10.1002/sscp.70152
BibTeX
@article{Sharma2025,
author = {Sharma, Abhishek and Pedavenkatagari, Narayana Reddy and Ettaboina, Santhosh Kumar and Nakka, Srinivas},
title = {A Green and Ultra‐Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Simultaneous Trace‐Level Quantification of Nitrosamine Drug Substance Related Impurities in Clozapine: Method Development, Validation, and Greenness Evaluation},
journal = {SEPARATION SCIENCE PLUS},
year = {2025},
volume = {8},
number = {11},
doi = {10.1002/sscp.70152}
}
EUVIMED