EUVIMEDEUVIMED entdecken
Crossref

An Optimized UHPLC Technique for the Identification and Quantification of the Related Impurities for Cedazuridine/Decitabine Combination and the Characterization of the Forced Degradation Products Through MS/MS

Anoop Bodapati, Bangaraiah Pagala

SEPARATION SCIENCE PLUS · 2025-05 · 8 (5)

DOI: 10.1002/sscp.70059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SEPARATION SCIENCE PLUS, online erschienen am 15.05.2025. Verfasst von Anoop Bodapati und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to develop and validate a sensitive, stability‐indicating ultra‐high performance liquid chromatography (UHPLC) method for the identification and characterization of forced degradation products of cedazuridine and decitabine using LC‐MS 2 . A UHPLC method was developed using an Acquity UHPLC BEH Shield RP‐18 column (50 mm × 1.0 mm, 1.7 µm) with a mobile phase of acetonitrile:heptane sulfonic acid pH 2.5/formic acid (30:70 v/v) at a flow rate of 0.5 mL/min. The method validation was performed by evaluating the parameters—specificity, linearity, accuracy, precision, robustness, ruggedness, and system suitability following ICH guidelines. Forced degradation studies were performed under acidic, alkaline, oxidation, thermal, photolytic, and hydrolytic conditions to evaluate the stability profile. Mass spectrometry analysis (LC‐MS 2 ) was conducted to characterize degradation products and propose their fragmentation pathways. The method demonstrated excellent linearity ( R 2 ≥ 0.999) within the tested concentration ranges, with acceptable %RSD values (≤ 1.25%), confirming high precision and accuracy. Forced degradation studies indicated that cedazuridine and decitabine were most susceptible to oxidative and acidic conditions, with purity thresholds exceeding purity angles, ensuring no significant interference from degradation products. LC‐MS/MS analysis successfully identified five major degradation products (DP‐1 to DP‐5), and their structures were proposed based on mass fragmentation patterns.

Zitieren

APA

Bodapati, A., & Pagala, B. (2025). An Optimized UHPLC Technique for the Identification and Quantification of the Related Impurities for Cedazuridine/Decitabine Combination and the Characterization of the Forced Degradation Products Through MS/MS. SEPARATION SCIENCE PLUS, 8(5). https://doi.org/10.1002/sscp.70059

Vancouver

Bodapati A, Pagala B. An Optimized UHPLC Technique for the Identification and Quantification of the Related Impurities for Cedazuridine/Decitabine Combination and the Characterization of the Forced Degradation Products Through MS/MS. SEPARATION SCIENCE PLUS. 2025;8(5). doi:10.1002/sscp.70059

BibTeX
@article{Bodapati2025,
  author = {Bodapati, Anoop and Pagala, Bangaraiah},
  title = {An Optimized UHPLC Technique for the Identification and Quantification of the Related Impurities for Cedazuridine/Decitabine Combination and the Characterization of the Forced Degradation Products Through MS/MS},
  journal = {SEPARATION SCIENCE PLUS},
  year = {2025},
  volume = {8},
  number = {5},
  doi = {10.1002/sscp.70059}
}
Kostenlos starten →