EUVIMEDEUVIMED entdecken
Crossref

Correction to “Sonographic Imaging of Vascular Thoracic Outlet Syndrome”

Sonography · 2026-06 · 13 (2)

DOI: 10.1002/sono.70072 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sonography, online erschienen am 12.05.2026.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

K. Lim, M. Fenech, and K. Russo, “ Sonographic Imaging of Vascular Thoracic Outlet Syndrome,” Sonography 12, no. 4 (2025): 569–582, https://doi.org/10.1002/sono.70018. The legend for Figure 9 “Pulsed wave Doppler images of the subclavian artery (SCA) in the costo-clavicular space. (A) Imaging of the SCA was acquired with the arm in a neutral position, and normal lumen color fill and vascular waveforms were demonstrated. (B) Imaging of the SCA was acquired with the arm in the Roos' position. There is an increase in the peak systolic velocity (PSV) from 74 cm/s in the neutral position, gained in B, to 311 cm/s. This resulted in a ratio of 4.2 indicating a 75%–99% vascular occlusion with the provocative maneuver, consistent with arterial thoracic outlet syndrome.” was incorrect. This should have read: Pulsed wave Doppler images of the subclavian artery (SCA) in the costo-clavicular space. (A) Imaging of the SCA was acquired with the arm in a neutral position, and normal lumen color fill and vascular waveforms were demonstrated. (B) Imaging of the SCA was acquired with the arm in the Roos' position. There is an increase in the peak systolic velocity (PSV) from 74 cm/s* in the neutral position to 311 cm/s in the Roo's position. This resulted in a greater than doubling of the PSV indicating a > 50% stenosis. Elevated PSV (311 cm/s) measured in the provocative maneuver with loss of early diastolic flow and spectral broadening indicate a SCA stenosis of greater than 70%. These findings are consistent with arterial thoracic outlet syndrome. *74 cm/s may be erroneous and impact on stenosis grading as the sample gate is not well-aligned to the flow vector of the artery. Perfect alignment was not technically possible due to difficulty in acquiring a Doppler angle of 60° or less and maintaining linear transducer contact around the clavicle (posterior acoustic shadowing at top right of image 9A). We apologize for this error.

Zitieren

APA

(2026). Correction to “Sonographic Imaging of Vascular Thoracic Outlet Syndrome”. Sonography, 13(2). https://doi.org/10.1002/sono.70072

Vancouver

Correction to “Sonographic Imaging of Vascular Thoracic Outlet Syndrome”. Sonography. 2026;13(2). doi:10.1002/sono.70072

BibTeX
@article{euvimed2026,
  title = {Correction to “Sonographic Imaging of Vascular Thoracic Outlet Syndrome”},
  journal = {Sonography},
  year = {2026},
  volume = {13},
  number = {2},
  doi = {10.1002/sono.70072}
}
Kostenlos starten →