An AI‐Guided Mechanotyping Instrument for Fully Automated Oocyte Quality Assessment
Small Methods · 2026-06 · 10 (12)
DOI: 10.1002/smtd.202502390 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small Methods, online erschienen am 06.05.2026. Verfasst von Yining Guo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China. Hauptthemen laut MEDLINE: Oocytes, Artificial Intelligence. Die Arbeit nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shenzhen Medical Research Fund, Shenzhen Science and Technology Program.
Abstract (Originalsprache)
The mechanical properties of oocytes are regarded as important indicators of their developmental potential. During fertilization, deviations from the normal mechanical range can hinder sperm penetration, ultimately reducing fertilization efficiency and compromising embryo quality. However, current methods for measuring oocyte mechanics often suffer from low automation levels and predominantly provide local, rather than whole‐cell, mechanical characterization. To address these limitations, we developed an AI‐guided µN‐scale mechanical measurement instrument for safe and automated oocyte quality assessment. The instrument integrates voice interaction with automated experimental workflows to control a magnetically actuated microgripper, which applies defined loading forces to induce micron‐scale compressive deformation of the oocyte. Combined with AI‐assisted object detection and image segmentation algorithms, the instrument captures cellular deformation in real time, enabling precise calculation of the oocyte's compressive modulus. This measurement instrument enables automated, quantitative, and non‐destructive evaluation of oocyte mechanical properties, providing an effective approach for oocyte quality screening in in vitro fertilization (IVF) and other assisted reproductive technologies (ART).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
- College of Mechanical Engineering, Hubei University of Technology, Hubei, China.
- College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing, China.
ORCID-Profile: Haifeng Xu
Förderung
- National Natural Science Foundation of China
- Shenzhen Medical Research Fund
- Shenzhen Science and Technology Program
- Shenzhen Science and Technology Innovation Program
Zitieren
APA
Guo, Y., Zhao, W., Sun, X., Huang, J., Chen, X., Lu, X., Cao, W., Liu, Y., & Xu, H. (2026). An AI‐Guided Mechanotyping Instrument for Fully Automated Oocyte Quality Assessment. Small Methods, 10(12). https://doi.org/10.1002/smtd.202502390
Vancouver
Guo Y, Zhao W, Sun X, Huang J, Chen X, Lu X, et al. An AI‐Guided Mechanotyping Instrument for Fully Automated Oocyte Quality Assessment. Small Methods. 2026;10(12). doi:10.1002/smtd.202502390
BibTeX
@article{Guo2026,
author = {Guo, Yining and Zhao, Wenshuo and Sun, Xueying and Huang, Jing and Chen, Xi and Lu, Xinyu and Cao, Wujing and Liu, Yuan and Xu, Haifeng},
title = {An AI‐Guided Mechanotyping Instrument for Fully Automated Oocyte Quality Assessment},
journal = {Small Methods},
year = {2026},
volume = {10},
number = {12},
doi = {10.1002/smtd.202502390}
}
EUVIMED