EUVIMEDEUVIMED entdecken
Crossref

Colorimetric Fabry‐Pérot Sensor with Hetero‐Structured Dielectric for Humidity Monitoring

Zhihuan Li, Lejie Tian, Wei Wu, Li Feng, Bakyt Khaniyev, Yerzhan Mukhametkarimov, Margulan Ibraimov, Feng Zhou, Weimin Liu, Jianxi Liu iD

Small Methods · 2025-04 · 9 (4)

DOI: 10.1002/smtd.202401485 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small Methods, online erschienen am 31.10.2024. Verfasst von Zhihuan Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Solidification Processing, MIIT Key Laboratory of Radiation Detection Materials and Devices, Center of Advanced Lubrication a…. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Natural Science Foundations of China, Research Fund of the State Key Laboratory of Solidification Processing, Science Fund of Shandong Laboratory of Advanced Materials and Green Manufacturing.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A full‐color colorimetric humidity sensor with high brightness is proposed by using a hetero‐structured dielectric film in a metal‐insulator‐metal (MIM) resonator. A humidity‐responsive polymer is designed to graft on top of a metal‐organic frameworks (MOFs) thin film (MOFs‐Polymer) as insulator layer in the resonator. Programmable tuning of reflected color is achieved by controlling the polymer thicknesses, and finite difference time domain simulation of light‐matter interactions at subwavelength scales proves the dependence of the reflected wavelength on dielectric layer thickness of the resonator. Vivid full‐color changing is realized during tracking humidity process due to swelling of the stimuli‐responsive polymer. Ultrafast response (≈0.75 s) is achieved for tracking trace H 2 O from H 2 O/methanol mixture, which is ≈10 4 faster than that of the pure polymer‐based MIM resonator. Meanwhile, the study observes significant spectral redshift because the porous MOFs film facilitates the preconcentration of external stimulus and improves the detection sensitivity of the resonator. Further, double‐channel anti‐counterfeiting multiplexing imaging is devised on the MIM resonator by photomask technology. Patterned encoding for security label is achieved on the MIM resonator by engineering humidity‐tunable pixels of Au/MOFs‐Polymer/Au and humidity‐invalid pixels of Au/MOFs/Au.

Schlagwörter

Stichwörter der Autor:innen

anti‐counterfeitingmetal‐insulator‐metalmetal–organic frameworkssensingstructure color

Autor:innen und Institutionen

  • State Key Laboratory of Solidification Processing, MIIT Key Laboratory of Radiation Detection Materials and Devices, Center of Advanced Lubrication and Seal Materials, School of Materials Science and Engineering, Northw…
  • Department of Physics and Technology, Al-Farabi Kazakh National University, Al-Farabi av. 71, Almaty, 050040, Kazakhstan.
  • State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000, P. R. China.

ORCID-Profile: Jianxi Liu

Förderung

  • National Natural Science Foundations of China
  • Research Fund of the State Key Laboratory of Solidification Processing
  • Science Fund of Shandong Laboratory of Advanced Materials and Green Manufacturing

Zitieren

APA

Li, Z., Tian, L., Wu, W., Feng, L., Khaniyev, B., Mukhametkarimov, Y., Ibraimov, M., Zhou, F., Liu, W., & Liu, J. (2025). Colorimetric Fabry‐Pérot Sensor with Hetero‐Structured Dielectric for Humidity Monitoring. Small Methods, 9(4). https://doi.org/10.1002/smtd.202401485

Vancouver

Li Z, Tian L, Wu W, Feng L, Khaniyev B, Mukhametkarimov Y, et al. Colorimetric Fabry‐Pérot Sensor with Hetero‐Structured Dielectric for Humidity Monitoring. Small Methods. 2025;9(4). doi:10.1002/smtd.202401485

BibTeX
@article{Li2025,
  author = {Li, Zhihuan and Tian, Lejie and Wu, Wei and Feng, Li and Khaniyev, Bakyt and Mukhametkarimov, Yerzhan and Ibraimov, Margulan and Zhou, Feng and Liu, Weimin and Liu, Jianxi},
  title = {Colorimetric Fabry‐Pérot Sensor with Hetero‐Structured Dielectric for Humidity Monitoring},
  journal = {Small Methods},
  year = {2025},
  volume = {9},
  number = {4},
  doi = {10.1002/smtd.202401485}
}
Kostenlos starten →