Hierarchically Rough rGO/HAp Nanocoatings on SLM Ti–6Al–4 V Implants for Enhanced Biointegration

Muhammad Usama Zaheer iD, Vahid Jahed iD, Rajveer Singh Rajaura iD, Fatemeh Rastegar Adib iD, Muhammad Hassan Razzaq iD, Gökhan Demirel iD, Mobarak Abu Mraheil, Thaqif El Khassawna iD, Mehmet Fatih Aycan iD, Yogendra Kumar Mishra iD

Small · 2026

DOI: 10.1002/smll.75211 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, 2026. Verfasst von Muhammad Usama Zaheer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Smart Materials, NanoSYD, Mads Clausen Institute, University of Southern Denmark, Sønderborg, Denmark. Hauptthemen laut MEDLINE: Titanium, Graphite, Prostheses and Implants, Durapatite. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union's Horizon 2020 research and innovation program, Scientific and Technological Research Council of Türkiye, Science and Higher Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Additive manufacturing of Ti–6Al–4V implants enables patient‐specific design, but process‐induced surface and microstructural variations can strongly affect biological performance. In this work, Ti64 samples with varying volumetric energy densities (VEDs) were fabricated by selective laser melting to examine the combined effects of processing and surface modification on cell response and antibacterial behavior. The specimens were surface activated by controlled acid etching and coated with hydroxyapatite/reduced graphene oxide (HAp/rGO) composite via electrophoretic deposition. Surface morphology, chemistry, and porosity were assessed using Scanning Electron Microscopy, X‐ray Photoelectron Spectroscopy, profilometry, micro‐CT. Micro‐CT showed higher internal porosity at lower VED, while a balance between densification and structural integrity was achieved at VED of 107 J mm − 3 . In vitro cytocompatibility demonstrated >90% viability for all samples, meeting ISO 10993‐5 requirements. Despite this, cell attachment depends on VED, the E63 condition exhibited the most uniform coverage after HAp/rGO coating, indicating an improved surface–cell interactions at lower VED. Antibacterial assays showed VED dependence; high‐VED‐E320 samples produced the highest biofilm formation even after coating, whereas low and intermediate VED conditions significantly reduced bacterial adhesion. Overall, biological functionality is observed to be governed by both coating and SLM parameters, with 107 J·mm − 3 offering the best combined structural, cytocompatible, and antibacterial performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumGraphiteProstheses and ImplantsDurapatiteCoated Materials, BiocompatibleAlloysSurface PropertiesPhotoelectron SpectroscopyAnimalsHumansPorosity

Stichwörter der Autor:innen

biointegrationcytocompatibilityhierarchical morphologyorthopedic SLM implantsrGO/HAp nanocoating

Substanzen

Titaniumtitanium alloy (TiAl6V4)GraphiteAlloysgraphene oxideDurapatiteCoated Materials, Biocompatible

Autor:innen und Institutionen

  • Smart Materials, NanoSYD, Mads Clausen Institute, University of Southern Denmark, Sønderborg, Denmark.
  • Department of Mechanical Engineering, Institute for Graduate School of Natural and Applied Sciences, Gazi University, Ankara, Türkiye.
  • Additive Manufacturing Technologies Application and Research Center - EKTAM, Gazi University, Ankara, Türkiye.
  • Experimental Trauma Surgery, Faculty of Medicine, Justus-Liebig-University, Giessen, Germany.
  • School of Engineering and Materials Science, Queen Mary University of London, London, UK.
  • Institute for Medical Microbiology, Justus-Liebig-University, Giessen, Germany.

ORCID-Profile: Muhammad Usama Zaheer, Vahid Jahed, Rajveer Singh Rajaura, Fatemeh Rastegar Adib, Muhammad Hassan Razzaq, Gökhan Demirel, Thaqif El Khassawna, Mehmet Fatih Aycan, Yogendra Kumar Mishra

Förderung

  • European Union's Horizon 2020 research and innovation program
  • Scientific and Technological Research Council of Türkiye
  • Science and Higher Education
  • NANOCHEM
  • BHJ Fonden
  • Fabrikant Mads Clausen Fonden
  • Svend Beck, Peter Holm og Vagn Jacobsens Almene Fond

Zitieren

APA

Zaheer, M. U., Jahed, V., Rajaura, R. S., Adib, F. R., Razzaq, M. H., Demirel, G., Mraheil, M. A., El Khassawna, T., Aycan, M. F., & Mishra, Y. K. (2026). Hierarchically Rough rGO/HAp Nanocoatings on SLM Ti–6Al–4 V Implants for Enhanced Biointegration. Small. https://doi.org/10.1002/smll.75211

Vancouver

Zaheer MU, Jahed V, Rajaura RS, Adib FR, Razzaq MH, Demirel G, et al. Hierarchically Rough rGO/HAp Nanocoatings on SLM Ti–6Al–4 V Implants for Enhanced Biointegration. Small. 2026. doi:10.1002/smll.75211

BibTeX
@article{Zaheer2026,
  author = {Zaheer, Muhammad Usama and Jahed, Vahid and Rajaura, Rajveer Singh and Adib, Fatemeh Rastegar and Razzaq, Muhammad Hassan and Demirel, Gökhan and Mraheil, Mobarak Abu and El Khassawna, Thaqif and Aycan, Mehmet Fatih and Mishra, Yogendra Kumar},
  title = {Hierarchically Rough rGO/HAp Nanocoatings on SLM Ti–6Al–4 V Implants for Enhanced Biointegration},
  journal = {Small},
  year = {2026},
  doi = {10.1002/smll.75211}
}
Kostenlos starten →