EUVIMEDEUVIMED entdecken
Crossref

Disulfide‐Linked Symmetrical Polydiacetylene as Visualized Temperature Sensor for Heatstroke Monitor

Xuan Zhang, Chenglong Qiu, Yongguang Zhang, Mengnan Zhao, Ying Qian, Yong Yang

Small · 2026

DOI: 10.1002/smll.74850 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, 2026. Verfasst von Xuan Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, People's Republic of China. Hauptthemen laut MEDLINE: Polyacetylene Polymer, Polyynes, Temperature, Heat Stroke. Die Arbeit nennt 66 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Body temperature is a key physiological indicator, requiring continuous, full‐range monitoring from normothermia to hyperthermia for effective heatstroke management. To address the limitations of mercury thermometers and existing sensors in visualized real‐time screening, three monomers S‐1, S‐2, and S‐3 featuring flexible aliphatic chains and ester terminals, anhydride terminals, and aromatic rings with amide hydrogen bonds and π–π stacking are designed and polymerized into Poly(S‐1), Poly(S‐2), and Poly(S‐3), respectively. Among these polydiacetylenes (PDAs) with symmetric functionalization, Poly(S‐1) exhibits a multi‐step, naked‐eye‐visible thermochromic transition within 35°C–43°C, attributed to its flexible aliphatic chains and ester linkages that enable side‐chain motion and main‐chain conformational changes at low temperatures. In contrast, the rigid structural motifs present in Poly(S‐2) and Poly(S‐3) introduce stronger intermolecular forces and higher energy barriers, necessitating elevated temperatures to induce comparable thermochromic transitions. Notably, Poly(S‐1) is successfully fabricated into a functional patch; its irreversible thermochromic nature within the physiological range meets the requirements of disposable medical devices, helping to prevent cross‐infection and facilitating temperature recording. This study enables precise tuning of the thermochromic temperature of PDA materials, expands their applications in biomedical monitoring and smart responsive materials, and offers design insights and theoretical foundations for developing next‐generation visual body temperature sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polyacetylene PolymerPolyynesTemperatureHeat StrokePolymers

Stichwörter der Autor:innen

body temperature monitoringheatstroke detectionpolydiacetylenessymmetric structuresthermochromic materialsvisual sensors

Substanzen

Polyacetylene PolymerpolydiacetylenePolyynesPolymers

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, People's Republic of China.
  • Department of Orthopedics, Fuzong Clinical Medical College of Fujian Medical University, 900 TH Hospital of Joint Logistics Support Force, PLA, Fuzhou, People's Republic of China.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Jiangsu Province
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Zhang, X., Qiu, C., Zhang, Y., Zhao, M., Qian, Y., & Yang, Y. (2026). Disulfide‐Linked Symmetrical Polydiacetylene as Visualized Temperature Sensor for Heatstroke Monitor. Small. https://doi.org/10.1002/smll.74850

Vancouver

Zhang X, Qiu C, Zhang Y, Zhao M, Qian Y, Yang Y. Disulfide‐Linked Symmetrical Polydiacetylene as Visualized Temperature Sensor for Heatstroke Monitor. Small. 2026. doi:10.1002/smll.74850

BibTeX
@article{Zhang2026,
  author = {Zhang, Xuan and Qiu, Chenglong and Zhang, Yongguang and Zhao, Mengnan and Qian, Ying and Yang, Yong},
  title = {Disulfide‐Linked Symmetrical Polydiacetylene as Visualized Temperature Sensor for Heatstroke Monitor},
  journal = {Small},
  year = {2026},
  doi = {10.1002/smll.74850}
}
Kostenlos starten →