Interfacial Charge Separation Engineering‐Modulated Multichannel Photoelectrochemical Biosensor Enabled by a Triple‐Responsive Nanolabel
Small · 2026-08 · 22 (47)
DOI: 10.1002/smll.74500 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small, online erschienen am 10.07.2026. Verfasst von Hongyuan Shang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hosp…. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation, Natural Science Foundation for Young Scientists of Shanxi Province, Shanxi Medical University Scientific Research Funds.
Abstract (Originalsprache)
Accurate biomarker detection is crucial for early and accurate disease diagnosis. Herein, a multiplexed biosensor capable of simultaneous electrochemical (EC) and photoelectrochemical (PEC) operation is fabricated using efficient, self‐templated In 2 S 3 /CuInS 2 (CIS) heterostructured nanotubes for the selective detection of bovine serum albumin (BSA). For the EC mode, the In 2 S 3 /CIS heterostructure exhibits a high differential pulse voltammetry (DPV) response arising from Cu + /Cu 2+ electron transfer, alongside excellent peroxidase‐mimetic activity toward H 2 O 2 . For the PEC mode, the n‐p type semiconducting In 2 S 3 /CIS hollow nanotubes not only quench the photocurrent signals of photoactive ZnIn 2 S 4 (ZIS) nanoflowers due to the competitive capture of light energy and consumption of electron donors; but also act as a peroxidase mimetic to generate insoluble precipitation. Furthermore, the steric hindrance effect from the In 2 S 3 /CIS heterostructure will further decrease the photocurrent signal output of ZIS. By integrating molecular imprinting technology, BSA can be specifically recognized and captured the imprinted cavities, leading to a significant decrease in both EC and photocurrent signals. Based on these multifunctional nanotubes, BSA is detected accurately with a wide linear range from 10 −20 mg·mL −1 to 10 −1 mg·mL −1 and a detection limit of 8.5 × 10 −21 mg·mL −1 . This multiplexed strategy provides a universal and efficient platform for clinical biomedicine and bioanalysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, China.
- College of Pharmacy, Shanxi Medical University, Taiyuan, PR China.
- Department of Anesthesiology, Shanxi Medical University, Taiyuan, China.
- College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, China.
- Department of Anesthesiology, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, China.
ORCID-Profile: Hongyuan Shang, Yunlan Li
Förderung
- National Natural Science Foundation
- Natural Science Foundation for Young Scientists of Shanxi Province
- Shanxi Medical University Scientific Research Funds
Zitieren
APA
Shang, H., Zhang, W., Li, J., Fan, J., Wei, J., Li, Y., & Zhang, W. (2026). Interfacial Charge Separation Engineering‐Modulated Multichannel Photoelectrochemical Biosensor Enabled by a Triple‐Responsive Nanolabel. Small, 22(47). https://doi.org/10.1002/smll.74500
Vancouver
Shang H, Zhang W, Li J, Fan J, Wei J, Li Y, et al. Interfacial Charge Separation Engineering‐Modulated Multichannel Photoelectrochemical Biosensor Enabled by a Triple‐Responsive Nanolabel. Small. 2026;22(47). doi:10.1002/smll.74500
BibTeX
@article{Shang2026,
author = {Shang, Hongyuan and Zhang, Wenjing and Li, Jiaxuan and Fan, Jie and Wei, Jingjing and Li, Yunlan and Zhang, Weiwei},
title = {Interfacial Charge Separation Engineering‐Modulated Multichannel Photoelectrochemical Biosensor Enabled by a Triple‐Responsive Nanolabel},
journal = {Small},
year = {2026},
volume = {22},
number = {47},
doi = {10.1002/smll.74500}
}
EUVIMED