EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High Sensitivity Cardiac Troponin I Detection via MP‐Locked Aptamer and Multimeric DNAzyme‐Coupled Hyperbranched Hybridization Chain Reaction

Sayantan Tripathy iD, Sahil Sharma, Ng Ka Wai, Siddhant Jaitpal, Anthony Dongchau, Saugat Bhattacharyya, Sonya R Wesselowski, Ashley B Saunders, Gerard L Coté, Samuel B Mabbott iD

Small · 2026-04 · 22 (20)

DOI: 10.1002/smll.202512096 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, online erschienen am 23.02.2026. Verfasst von Sayantan Tripathy und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA. Hauptthemen laut MEDLINE: Troponin I, Aptamers, Nucleotide, DNA, Catalytic, Nucleic Acid Hybridization. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, United States-Ireland-Northern Ireland R&D Partnership supplement.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Timely and sensitive detection of cardiac troponin I (cTnI) is critical for early diagnosis of myocardial infarction, particularly at the point‐of‐care. Herein, we present a novel colorimetric biosensing platform for high‐sensitivity detection of cardiac troponin I (cTnI). The platform integrates magnetic particle (MP) anchored locked aptamers, stabilized by short complementary strands to minimize nonspecific folding and background activation prior to target binding, with hyperbranched hybridization chain reaction (HCR) and catalytic DNA (DNAzyme) nanocomplex–mediated signal amplification. This enzyme‐free amplification system detects cTnI directly in 25–30 min, with a calculated detection limit of 0.25 ng L −1 , a wide dynamic range of 0.5–50 000 ng L −1 , and a coefficient of variation below 5% using just 25 µL of patient serum. The developed assay was evaluated using both human and canine serum samples. To assess classification performance, three distinct hyperparameter optimization strategies were applied to a reduced feature space. The model achieved an accuracy of 90.91% and a recall of 89.89% for human samples, and an accuracy of 83.33% with a recall of 85.71% for canine samples. Blind testing with human serum samples further confirmed the robustness of the platform, showing an overall accuracy of around 90%. This integrated biosensing and machine learning framework enables rapid and sensitive detection of cardiac troponin I, demonstrating strong potential for myocardial infarction diagnosis across species in a pre‐clinical setting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin IAptamers, NucleotideDNA, CatalyticNucleic Acid HybridizationHumansAnimalsBiosensing TechniquesDogsColorimetry

Stichwörter der Autor:innen

DNAzymehyperbranched hybridization chain reactionlocked aptamermachine learningmyocardial infarction

Substanzen

Troponin IAptamers, NucleotideDNA, Catalytic

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA.
  • Center for Remote Health Technologies and Systems, Texas A&M University, College Station, Texas, USA.
  • School of Computing, Engineering and Intelligent Systems, Ulster University, Londonderry, Northern Ireland, UK.
  • Department of Small Animal Clinical Sciences, College of Veterinary Medicine & Biomedical Sciences, Texas A&M University, College Station, Texas, USA.
  • Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, USA.

ORCID-Profile: Sayantan Tripathy, Samuel B Mabbott

Förderung

  • National Science Foundation
  • United States-Ireland-Northern Ireland R&D Partnership supplement

Zitieren

APA

Tripathy, S., Sharma, S., Wai, N. K., Jaitpal, S., Dongchau, A., Bhattacharyya, S., Wesselowski, S. R., Saunders, A. B., Coté, G. L., & Mabbott, S. B. (2026). High Sensitivity Cardiac Troponin I Detection via MP‐Locked Aptamer and Multimeric DNAzyme‐Coupled Hyperbranched Hybridization Chain Reaction. Small, 22(20). https://doi.org/10.1002/smll.202512096

Vancouver

Tripathy S, Sharma S, Wai NK, Jaitpal S, Dongchau A, Bhattacharyya S, et al. High Sensitivity Cardiac Troponin I Detection via MP‐Locked Aptamer and Multimeric DNAzyme‐Coupled Hyperbranched Hybridization Chain Reaction. Small. 2026;22(20). doi:10.1002/smll.202512096

BibTeX
@article{Tripathy2026,
  author = {Tripathy, Sayantan and Sharma, Sahil and Wai, Ng Ka and Jaitpal, Siddhant and Dongchau, Anthony and Bhattacharyya, Saugat and Wesselowski, Sonya R and Saunders, Ashley B and Coté, Gerard L and Mabbott, Samuel B},
  title = {High Sensitivity Cardiac Troponin I Detection via MP‐Locked Aptamer and Multimeric DNAzyme‐Coupled Hyperbranched Hybridization Chain Reaction},
  journal = {Small},
  year = {2026},
  volume = {22},
  number = {20},
  doi = {10.1002/smll.202512096}
}