Smartphone‐Assisted Wireless Ultrasensitive Nitrite Detection in Food Samples via Hierarchical MXene/NiCoMn‐LDH/Sulfide Heterostructure on Flexible Laser‐Induced Graphene Electrode
Small · 2025-12 · 21 (51)
DOI: 10.1002/smll.202510411 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small, online erschienen am 12.11.2025. Verfasst von Kugalur Shanmugam Ranjith und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Energy and Material Engineering, Dongguk University-Seoul, Seoul, 04620, Republic of Korea. Hauptthemen laut MEDLINE: Graphite, Smartphone, Nitrites, Food Analysis. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea (NRF), Korean Government (MSIT), Rural Development Administration.
Abstract (Originalsprache)
Designing a smartphone in‐built, wireless, ultrasensitive hybrid heterostructure‐based sensor is challenging, but it is potentially crucial for achieving efficient electrochemical responses related to real‐time food safety monitoring. Herein, the pioneering design of a few‐layered MXene‐tagged NiCoMn‐layered double hydroxide (LDH)/amorphous sulfide (MXe/NiCoMn‐LDH/S) hollow spheres were fabricated and tagged onto a laser‐induced graphene (LIG) electrode for smartphone‐based electrochemical detection of nitrite (NO 2 − ). Benefiting from the unique structural and compositional advantages of MXe/NiCoMn‐LDH/S integrated on a flexible LIG electrode platform, the sensor achieved a linear detection range from 0.90 to 25 µM, and a low detection limit of 0.21 µM, along with a high sensitivity of 11.88 µA µM −1 cm −2 . Additionally, using the LSV, the sensor demonstrated a wider linear range from 10 to 860 µM with a detection limit of 7.38 µM and sensitivity of 1.15 µA µM −1 cm −2 . It also demonstrated strong anti‐interference capability against various organic and inorganic substances, along with excellent reproducibility, repeatability, and reusability, as well as outstanding stability over 30 days. The proposed point‐of‐care electrochemical system, featuring a portable and affordable LIG electrode design, along with compact smartphone integrity, highlights its advantages over traditional benchtop potentiostats in real‐time water quality monitoring in rural and low‐resource areas.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Energy and Material Engineering, Dongguk University-Seoul, Seoul, 04620, Republic of Korea.
- Department of Biological Sciences and Bioengineering, Nano Bio High-Tech Materials Research Center, Inha University, Incheon, 22212, Republic of Korea.
ORCID-Profile: Yun Suk Huh
Förderung
- National Research Foundation of Korea (NRF)
- Korean Government (MSIT)
- Rural Development Administration
Zitieren
APA
Ranjith, K. S., Mohammadi, A., Vilian, A. T. E., Park, Y., Raju, G. S. R., Huh, Y. S., & Han, Y. K. (2025). Smartphone‐Assisted Wireless Ultrasensitive Nitrite Detection in Food Samples via Hierarchical MXene/NiCoMn‐LDH/Sulfide Heterostructure on Flexible Laser‐Induced Graphene Electrode. Small, 21(51). https://doi.org/10.1002/smll.202510411
Vancouver
Ranjith KS, Mohammadi A, Vilian ATE, Park Y, Raju GSR, Huh YS, et al. Smartphone‐Assisted Wireless Ultrasensitive Nitrite Detection in Food Samples via Hierarchical MXene/NiCoMn‐LDH/Sulfide Heterostructure on Flexible Laser‐Induced Graphene Electrode. Small. 2025;21(51). doi:10.1002/smll.202510411
BibTeX
@article{Ranjith2025,
author = {Ranjith, Kugalur Shanmugam and Mohammadi, Ali and Vilian, A T Ezhil and Park, Yonghyeon and Raju, Ganji Seeta Rama and Huh, Yun Suk and Han, Young-Kyu},
title = {Smartphone‐Assisted Wireless Ultrasensitive Nitrite Detection in Food Samples via Hierarchical MXene/NiCoMn‐LDH/Sulfide Heterostructure on Flexible Laser‐Induced Graphene Electrode},
journal = {Small},
year = {2025},
volume = {21},
number = {51},
doi = {10.1002/smll.202510411}
}
EUVIMED