EUVIMEDEUVIMED entdecken
Crossref

Droplet Digital Enzymatic Recycling for Single‐Molecule Homogeneous Immunoassay

Yan Su, Xiaoya Wu, Xiaonan Sun, Qiushi Hu, Juan Jiao, Jiali Ma, Yingjun Li, Chongsi Sun, Wei Guo iD, Lei Zhou iD

Small · 2025-09 · 21 (35)

DOI: 10.1002/smll.202503786 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, online erschienen am 11.07.2025. Verfasst von Yan Su und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Biopharmaceutical Preparation and Delivery, PLA Key Laboratory of Biopharmaceutical Production & Formulation Engineering, Ins…. Hauptthemen laut MEDLINE: Immunoassay, Microfluidics. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Beijing Natural Science Foundation, Autonomous Deployment Project of State Key Laboratory of Biopharmaceutical Preparation and Delivery.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The merge of droplet microfluidics with single‐molecule homogeneous immunoassay (SiMHoI) provides a transformative tool for biomedical diagnosis with high sensitivity, simplified workflow and reduced reagent consumption. Existing droplet‐based SiMHoIs use polymerase chain reaction for single‐molecular protein signal amplification; and thus, suffer from the intrinsic deficiencies of intensive instrument dependence, high background interference, and redundant reaction time. To tackle these limitations, an enzymatic recycling (ER) reaction is introduced into the microdroplets as an isothermal amplification mechanism. This approach utilizes antibody‐ or aptamer‐labeled nucleic acid probes to capture trace amounts of targets confined in the microdroplets at a single‐ or sub‐single‐molecule level. Single‐target fluorescence signal is then amplified via an in‐droplet ER reaction with molecular beacons. This strategy eliminates the reliance on thermal cycling, and achieves selective droplet illumination within 20 min. The self‐noise suppression mechanism of the in‐droplet ER reaction enhances the positive‐to‐negative ratio nearly 20‐fold compared to the bulk‐phase reaction and reduce the detection limit to 10⁻¹⁸ m . Clinical validation with human serum specimens shows excellent consistency with flow cytometry ( P > 0.05). The isothermal signal amplification approach proposed here upgrades current droplet‐based molecular diagnostic platforms, and enables an engineering solution for detection of ultra‐low‐abundance biomarkers at preclinical stage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ImmunoassayMicrofluidicsHumansAptamers, Nucleotide

Stichwörter der Autor:innen

droplet microfluidicsearly‐stage diagnosticsenzymatic recyclingsingle molecule homogeneous immunoassay

Substanzen

Aptamers, Nucleotide

Autor:innen und Institutionen

  • State Key Laboratory of Biopharmaceutical Preparation and Delivery, PLA Key Laboratory of Biopharmaceutical Production & Formulation Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, 1…
  • University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Department of Cardiology, Second Medical Center of PLA General Hospital, Beijing, 100853, China.
  • Biosafety Research Center Yangtze River Delta in Zhangjiagang, Zhangjiagang, Suzhou, 215611, China.
  • Department of Clinical Laboratory, Seventh Medical Center of PLA General Hospital, Beijing, 100007, China.

ORCID-Profile: Wei Guo, Lei Zhou

Förderung

  • National Key Research and Development Program of China
  • Beijing Natural Science Foundation
  • Autonomous Deployment Project of State Key Laboratory of Biopharmaceutical Preparation and Delivery
  • Natural Science Foundation of Beijing Municipality

Zitieren

APA

Su, Y., Wu, X., Sun, X., Hu, Q., Jiao, J., Ma, J., Li, Y., Sun, C., Guo, W., & Zhou, L. (2025). Droplet Digital Enzymatic Recycling for Single‐Molecule Homogeneous Immunoassay. Small, 21(35). https://doi.org/10.1002/smll.202503786

Vancouver

Su Y, Wu X, Sun X, Hu Q, Jiao J, Ma J, et al. Droplet Digital Enzymatic Recycling for Single‐Molecule Homogeneous Immunoassay. Small. 2025;21(35). doi:10.1002/smll.202503786

BibTeX
@article{Su2025,
  author = {Su, Yan and Wu, Xiaoya and Sun, Xiaonan and Hu, Qiushi and Jiao, Juan and Ma, Jiali and Li, Yingjun and Sun, Chongsi and Guo, Wei and Zhou, Lei},
  title = {Droplet Digital Enzymatic Recycling for Single‐Molecule Homogeneous Immunoassay},
  journal = {Small},
  year = {2025},
  volume = {21},
  number = {35},
  doi = {10.1002/smll.202503786}
}
Kostenlos starten →