Effect of Internal Electrostatic Fields on Self‐Powered X‐Ray Detectors with High Sensitivity and Low Detection Limits in Polar Oxide Crystals α/ β ‐BaTeMo 2 O 9
Small · 2025-06 · 21 (24)
DOI: 10.1002/smll.202502928 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small, online erschienen am 18.04.2025. Verfasst von Fuai Hu und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Crystal Materials and Institute of Crystal Materials, Shandong University, Jinan, 250100, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Qilu Young Scholar of Shandong University, Taishan Scholar Foundation of Shandong Province.
Abstract (Originalsprache)
Self‐powered X‐ray detectors enable operating without applying bias, enabling detector portability and making them highly valuable in the industrial and medical fields. This study demonstrates high‐performance self‐powered detectors using polar α ‐BaTeMo 2 O 9 ( α ‐BTM) and β ‐BaTeMo 2 O 9 ( β ‐BTM) oxide crystals. It is proven that the carriers are driven by the internal electrostatic field along the polar axis, and the internal electrostatic field has a favorable effect on the polar oxide crystal self‐powered X‐ray detector. The β ‐BTM self‐powered detector has a sensitivity of 300.2 µCGy air −1 cm −2 under 40 keV X‐rays, which is 15 times that of α ‐Se detectors (20 µCGy air −1 cm −2 ). The polar structure simultaneously addresses the inherent trade‐off between dark current and photocurrent enhancement observed in conventional detectors. The polarization structure of α ‐BTM and β ‐BTM crystals leads to the macroscopic polarization along the polar axis, resulting in internal electrostatic fields of 34 and 66 V mm −1 . Furthermore, the ion activation energies of BTM are larger than 828 meV, which is higher than that of most perovskite materials, resulting in excellent stability and low dark current. The breakthrough performance stems from the synergistic effects of built‐in polarization fields and robust crystalline structure, opening new avenues for portable radiation detection technologies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Crystal Materials and Institute of Crystal Materials, Shandong University, Jinan, 250100, China.
ORCID-Profile: Zeliang Gao
Förderung
- National Natural Science Foundation of China
- Qilu Young Scholar of Shandong University
- Taishan Scholar Foundation of Shandong Province
Zitieren
APA
Hu, F., Guo, F., Mu, W., Cao, T., Wang, L., & Gao, Z. (2025). Effect of Internal Electrostatic Fields on Self‐Powered X‐Ray Detectors with High Sensitivity and Low Detection Limits in Polar Oxide Crystals α/ β ‐BaTeMo 2 O 9. Small, 21(24). https://doi.org/10.1002/smll.202502928
Vancouver
Hu F, Guo F, Mu W, Cao T, Wang L, Gao Z. Effect of Internal Electrostatic Fields on Self‐Powered X‐Ray Detectors with High Sensitivity and Low Detection Limits in Polar Oxide Crystals α/ β ‐BaTeMo 2 O 9. Small. 2025;21(24). doi:10.1002/smll.202502928
BibTeX
@article{Hu2025,
author = {Hu, Fuai and Guo, Feifei and Mu, Wenxiang and Cao, Tingting and Wang, Lei and Gao, Zeliang},
title = {Effect of Internal Electrostatic Fields on Self‐Powered X‐Ray Detectors with High Sensitivity and Low Detection Limits in Polar Oxide Crystals α/ β ‐BaTeMo 2 O 9},
journal = {Small},
year = {2025},
volume = {21},
number = {24},
doi = {10.1002/smll.202502928}
}
EUVIMED