EUVIMEDEUVIMED entdecken
Crossref

Reference‐Attached pH Nanosensor for Accurately Monitoring the Rapid Kinetics of Intracellular H + Oscillations

Ming-Yong Wen, Yu-Ting Qi, Yu-Ting Jiao, Xin-Wei Zhang iD, Wei-Hua Huang iD

Small · 2025

DOI: 10.1002/smll.202406796 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, 2025. Verfasst von Ming-Yong Wen und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Nanotechnology, Protons. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Technologies Research and Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intracellular pH (pHi) is an essential indicator of cellular metabolic activity, as its transient or small shift can significantly impact cellular homeostasis and reflect the cellular events. Real‐time and precise tracking of these rapid pH changes within a single living cell is therefore important. However, achieving high dynamic response performance (subsecond) pH detection inside a living cell with high accuracy remains a challenge. Here a reference‐attached pH nanosensor (R‐pH‐nanosensor) with fast and precise pHi sensing performance is introduced. The nanosensor comprises a highly conductive H + ‐sensitive IrRuOx nanowire (SiC@IrRuOx NW) as the intracellular working electrode and a SiC@Ag/AgCl NW as an intracellular reference electrode (RE) to diminish the interferences arising from cell membrane potential fluctuations. This whole‐inside‐cell detection mode ensures that the entire potential detection circuit is located within the same cell, and the R‐pH‐nanosensor is able to quantify the mild acidification of cytosol and completely record the fast pH variation within a single cell. It also enables real‐time potentiometric monitoring of the pHi oscillations, which synchronize with the glycolysis oscillations in cancer cells. Furthermore, the asymmetry in glycolysis oscillations wave is disclosed and the inhibitory effect of just lactate to glycolysis oscillations is further confirmed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesNanotechnologyProtonsHydrogen-Ion ConcentrationHumansNanowiresKineticsGlycolysis

Stichwörter der Autor:innen

biosensorsglycolysisintracellular pH oscillationsmetabolismpotentiometry

Substanzen

Protons

Autor:innen und Institutionen

  • College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China.
  • Department of Hepatobiliary and Pancreatic Surgery, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China.

ORCID-Profile: Xin-Wei Zhang, Wei-Hua Huang

Förderung

  • National Natural Science Foundation of China
  • Key Technologies Research and Development Program

Zitieren

APA

Wen, M. Y., Qi, Y. T., Jiao, Y. T., Zhang, X. W., & Huang, W. H. (2025). Reference‐Attached pH Nanosensor for Accurately Monitoring the Rapid Kinetics of Intracellular H + Oscillations. Small. https://doi.org/10.1002/smll.202406796

Vancouver

Wen MY, Qi YT, Jiao YT, Zhang XW, Huang WH. Reference‐Attached pH Nanosensor for Accurately Monitoring the Rapid Kinetics of Intracellular H + Oscillations. Small. 2025. doi:10.1002/smll.202406796

BibTeX
@article{Wen2025,
  author = {Wen, Ming-Yong and Qi, Yu-Ting and Jiao, Yu-Ting and Zhang, Xin-Wei and Huang, Wei-Hua},
  title = {Reference‐Attached pH Nanosensor for Accurately Monitoring the Rapid Kinetics of Intracellular H + Oscillations},
  journal = {Small},
  year = {2025},
  doi = {10.1002/smll.202406796}
}
Kostenlos starten →