EUVIMEDEUVIMED entdecken
Crossref

Battery‐Free, Wireless Multi‐Modal Sensor, and Actuator Array System for Pressure Injury Prevention

Hyeonseok Han, Hyunwoo Park, Seokjoo Cho, Sung-Uk Lee, Jungrak Choi, Ji-Hwan Ha, Jaeho Park, Young Jung, Hyunjin Kim, Junseong Ahn, Yeong Jae Kwon, Yong Suk Oh und 2 weitere

Small · 2024-12 · 20 (50)

DOI: 10.1002/smll.202405493 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, 2024-08. Verfasst von Hyeonseok Han und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea. Hauptthemen laut MEDLINE: Wireless Technology, Pressure Ulcer, Pressure. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: Technology Innovation Program (Development of Heterogeneous Multi-Sensor Micro-System Platform) funded By the Ministry of Trade, Industry & Energy (MOTIE, Kore…, the National Research Foundation of Korea(NRF) grant funded by the Korea government(MSIT).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Simultaneous monitoring of critical parameters (e.g., pressure, shear, and temperature) at bony prominences is essential for the prevention of pressure injuries in a systematic manner. However, the development of wireless sensor array for accurate mapping of risk factors has been limited due to the challenges in the convergence of wireless technologies and wearable sensor arrays with a thin and small form factor. Herein, a battery‐free, wireless, miniaturized multi‐modal sensor array is introduced for continuous mapping of pressure, shear, and temperature at skin interfaces. The sensor array includes an integrated pressure and shear sensor consisting of 3D strain gauges and micromachined components. The mechanically decoupled design of the integrated sensor enables reliable data acquisition of pressure and shear at skin interfaces without the need for additional data processing. The sensor platform enables the analysis of interplay among localized pressure, shear, and temperature in response to changes in the patient's movement, posture, and bed inclination. The validation trials using a novel combination of wireless sensor arrays and customized pneumatic actuator demonstrate the efficacy of the platform in continuous monitoring and efficient redistribution of pressure and shear without repositioning, thereby improving the patient's quality of life.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wireless TechnologyPressure UlcerPressureHumansWearable Electronic DevicesMonitoring, Physiologic

Stichwörter der Autor:innen

battery‐freepneumatic actuatorpressure and shear sensorspressure injurieswireless sensor array

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
  • School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
  • Advanced 3D Printing Technology Development Division, Korea Atomic Energy Research Institute, Daejeon, 34057, Republic of Korea.
  • Electronics and Telecommunications Research Institute (ETRI), Daejeon, 34129, Republic of Korea.
  • Department of Mechanical Engineering, Pukyong National University, Busan, 48513, Republic of Korea.
  • Department of Electro-Mechanical Systems Engineering, Korea University, Sejong, 30019, Republic of Korea.

ORCID-Profile: Inkyu Park

Förderung

  • Technology Innovation Program (Development of Heterogeneous Multi-Sensor Micro-System Platform) funded By the Ministry of Trade, Industry & Energy (MOTIE, Kore…
  • the National Research Foundation of Korea(NRF) grant funded by the Korea government(MSIT)

Zitieren

APA

Han, H., Park, H., Cho, S., Lee, S. U., Choi, J., Ha, J. H., Park, J., Jung, Y., Kim, H., Ahn, J., Kwon, Y. J., Oh, Y. S., Je, M., & Park, I. (2024). Battery‐Free, Wireless Multi‐Modal Sensor, and Actuator Array System for Pressure Injury Prevention. Small, 20(50). https://doi.org/10.1002/smll.202405493

Vancouver

Han H, Park H, Cho S, Lee SU, Choi J, Ha JH, et al. Battery‐Free, Wireless Multi‐Modal Sensor, and Actuator Array System for Pressure Injury Prevention. Small. 2024;20(50). doi:10.1002/smll.202405493

BibTeX
@article{Han2024,
  author = {Han, Hyeonseok and Park, Hyunwoo and Cho, Seokjoo and Lee, Sung-Uk and Choi, Jungrak and Ha, Ji-Hwan and Park, Jaeho and Jung, Young and Kim, Hyunjin and Ahn, Junseong and Kwon, Yeong Jae and Oh, Yong Suk and Je, Minkyu and Park, Inkyu},
  title = {Battery‐Free, Wireless Multi‐Modal Sensor, and Actuator Array System for Pressure Injury Prevention},
  journal = {Small},
  year = {2024},
  volume = {20},
  number = {50},
  doi = {10.1002/smll.202405493}
}
Kostenlos starten →