Shortwave Infrared Imaging of a Quantum Dot‐Based Magnetic Guidewire Toward Non‐Fluoroscopic Peripheral Vascular Interventions
Small · 2025-01 · 21 (3)
DOI: 10.1002/smll.202404251 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small, online erschienen am 23.08.2024. Verfasst von Junsun Hwang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea. Hauptthemen laut MEDLINE: Quantum Dots, Infrared Rays. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 100 Literaturangaben. Gefördert von: National Convergence Research of Scientific Challenges, Daegu Gyeongbuk Institute of Science and Technology.
Abstract (Originalsprache)
Peripheral vascular interventions (PVIs) offer several benefits to patients with lower extremity arterial diseases, including reduced pain, simpler anesthesia, and shorter recovery time, compared to open surgery. However, to monitor the endovascular tools inside the body, PVIs are conducted under X‐ray fluoroscopy, which poses serious long‐term health risks to physicians and patients. Shortwave infrared (SWIR) imaging of quantum dots (QDs) has shown great potential in bioimaging due to the non‐ionizing penetration of SWIR light through tissues. In this paper, a QD‐based magnetic guidewire and its system is introduced that allows X‐ray‐free detection under SWIR imaging and precise steering via magnetic manipulation. The QD magnetic guidewire contains a flexible silicone tube encapsulating a QD polydimethylsiloxane (PDMS) composite, where HgCdSe/HgS/CdS/CdZnS/ZnS/SiO 2 core/multi‐shell QDs are dispersed in the PDMS matrix for SWIR imaging upon near‐infrared excitation, as well as a permanent magnet for magnetic steering. The SWIR penetration of the QD magnetic guidewire is investigated within an artificial tissue model (1% Intralipid) and explore the potential for non‐fluoroscopic PVIs within a vascular phantom model. The QD magnetic guidewire is biocompatible in its entirety, with excellent resistance to photobleaching and chemical alteration, which is a promising sign for its future clinical implementation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea.
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea.
- Robotics and Mechatronics Engineering Research Center, DGIST, Daegu, 42988, Republic of Korea.
- Institute of Mechanical Engineering, École polytechnique fédérale de Lausanne (EPFL), Lausanne, 1015, Switzerland.
- Division of Biotechnology, DGIST, Daegu, 42988, Republic of Korea.
- Division of Nanotechnology, DGIST, Daegu, 42988, Republic of Korea.
ORCID-Profile: Junsun Hwang, Beomjoo Kim, Chaewon Jin, Gyudong Lee, Sung Jun Lim, Jin-Young Kim, Hongsoo Choi
Förderung
- National Convergence Research of Scientific Challenges
- Daegu Gyeongbuk Institute of Science and Technology
Zitieren
APA
Hwang, J., Kim, B., Jin, C., Lee, G., Jeong, H., Lee, H., Noh, J., Lim, S. J., Kim, J. Y., & Choi, H. (2025). Shortwave Infrared Imaging of a Quantum Dot‐Based Magnetic Guidewire Toward Non‐Fluoroscopic Peripheral Vascular Interventions. Small, 21(3). https://doi.org/10.1002/smll.202404251
Vancouver
Hwang J, Kim B, Jin C, Lee G, Jeong H, Lee H, et al. Shortwave Infrared Imaging of a Quantum Dot‐Based Magnetic Guidewire Toward Non‐Fluoroscopic Peripheral Vascular Interventions. Small. 2025;21(3). doi:10.1002/smll.202404251
BibTeX
@article{Hwang2025,
author = {Hwang, Junsun and Kim, Beomjoo and Jin, Chaewon and Lee, Gyudong and Jeong, Hwajun and Lee, Hyunki and Noh, Jonggu and Lim, Sung Jun and Kim, Jin-Young and Choi, Hongsoo},
title = {Shortwave Infrared Imaging of a Quantum Dot‐Based Magnetic Guidewire Toward Non‐Fluoroscopic Peripheral Vascular Interventions},
journal = {Small},
year = {2025},
volume = {21},
number = {3},
doi = {10.1002/smll.202404251}
}
EUVIMED