Fachartikel in der Zeitschrift Small, online erschienen am 03.04.2023. Verfasst von Dohwan Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA. Hauptthemen laut MEDLINE: Herpesvirus 1, Cercopithecine, COVID-19, Influenza, Human. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Georgia Institute of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Severe acute respiratory syndrome‐coronavirus 2 (SARS‐CoV‐2) continues to threaten lives by evolving into new variants with greater transmissibility. Although lateral flow assays (LFAs) are widely used to self‐test for coronavirus disease 2019 (COVID‐19), these tests suffer from low sensitivity leading to a high rate of false negative results. In this work, a multiplexed lateral flow assay is reported for the detection of SARS‐CoV‐2 and influenza A and B viruses in human saliva with a built‐in chemical amplification of the colorimetric signal for enhanced sensitivity. To automate the amplification process, the paper‐based device is integrated with an imprinted flow controller, which coordinates the routing of different reagents and ensures their sequential and timely delivery to run an optimal amplification reaction. Using the assay, SARS‐CoV‐2 and influenza A and B viruses can be detected with ≈25x higher sensitivity than commercial LFAs, and the device can detect SARS‐CoV‐2‐positive patient saliva samples missed by commercial LFAs. The technology provides an effective and practical solution to enhance the performance of conventional LFAs and will enable sensitive self‐testing to prevent virus transmission and future outbreaks of new variants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Herpesvirus 1, CercopithecineCOVID-19Influenza, HumanHumansSARS-CoV-2PaintSensitivity and Specificity

Stichwörter der Autor:innen

SARS-CoV-2capillary flow controlinfluenza A & Blateral flow assayspoint-of-care testing

Autor:innen und Institutionen

  • School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.

ORCID-Profile: Dohwan Lee, A Fatih Sarioglu

Förderung

  • Georgia Institute of Technology

Zitieren

APA

Lee, D., Ozkaya-Ahmadov, T., & Sarioglu, A. F. (2023). Chemically Amplified Multiplex Detection of SARS‐CoV‐2 and Influenza A and B Viruses via Paint‐Programmed Lateral Flow Assays. Small, 19(27). https://doi.org/10.1002/smll.202208035

Vancouver

Lee D, Ozkaya-Ahmadov T, Sarioglu AF. Chemically Amplified Multiplex Detection of SARS‐CoV‐2 and Influenza A and B Viruses via Paint‐Programmed Lateral Flow Assays. Small. 2023;19(27). doi:10.1002/smll.202208035

BibTeX
@article{Lee2023,
  author = {Lee, Dohwan and Ozkaya-Ahmadov, Tevhide and Sarioglu, A Fatih},
  title = {Chemically Amplified Multiplex Detection of SARS‐CoV‐2 and Influenza A and B Viruses via Paint‐Programmed Lateral Flow Assays},
  journal = {Small},
  year = {2023},
  volume = {19},
  number = {27},
  doi = {10.1002/smll.202208035}
}
Kostenlos starten →