EUVIMEDEUVIMED entdecken
Crossref

Closed Cyclic DNA Machine for Sensitive Logic Operation and APE1 Detection

Qingli Chai, Jinyang Chen iD, Shasha Zeng, Ting Zhu, Jintao Chen, Chunjiao Qi, Guobin Mao, Yucheng Liu

Small · 2023-06 · 19 (23)

DOI: 10.1002/smll.202207736 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, online erschienen am 14.03.2023. Verfasst von Qingli Chai und 7 weiteren Autor:innen. Beteiligte Einrichtung: Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi, Hube…. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 61-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hubei Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

DNA self‐assembly has been developed as a kind of robust signal amplification strategy, but most of reported assembly pathways are programmed to amplify signal in one direction. Herein, based on mutual‐activated cascade cycle of hybridization chain reaction (HCR) and catalytic hairpin assembly (CHA), a closed cycle circuit (CCC) based DNA machine is developed for sensitive logic operation and molecular recognition. Benefiting from the synergistically accelerated signal amplification, the closed cyclic DNA machine enabled the logic computing with strong and significant output signals even at weak input signals. The typical logic operations such as OR, YES, AND, INHIBIT, NOR, and NAND gate, are conveniently and clearly executed with this DNA machine through rational design of the input and computing elements. Moreover, by integrating the target recognition module with the CCC module, the proposed DNA machine is further employed in the homogeneous detection of apurinic/apyrimidinic endonuclease 1 (APE1). The precise recognition and exponential signal amplification facilitated the highly selective and sensitive detection of APE1 with limit of detection (LOD) of 7.8 × 10 −5 U mL −1 . Besides, the normal cells and tumor cells are distinguished unambiguously by this method according to the detected concentration difference of cellular APE1, which indicates the robustness and practicability of this method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesDNANucleic Acid HybridizationLogicLimit of Detection

Stichwörter der Autor:innen

APE1 detectionDNA machinefluorescencelogic operation

Substanzen

DNA

Autor:innen und Institutionen

  • Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi, Hubei, 435002, China.
  • Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
  • Core Facility of Wuhan University, Wuhan, Hubei, 430072, China.

ORCID-Profile: Jinyang Chen

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hubei Province

Zitieren

APA

Chai, Q., Chen, J., Zeng, S., Zhu, T., Chen, J., Qi, C., Mao, G., & Liu, Y. (2023). Closed Cyclic DNA Machine for Sensitive Logic Operation and APE1 Detection. Small, 19(23). https://doi.org/10.1002/smll.202207736

Vancouver

Chai Q, Chen J, Zeng S, Zhu T, Chen J, Qi C, et al. Closed Cyclic DNA Machine for Sensitive Logic Operation and APE1 Detection. Small. 2023;19(23). doi:10.1002/smll.202207736

BibTeX
@article{Chai2023,
  author = {Chai, Qingli and Chen, Jinyang and Zeng, Shasha and Zhu, Ting and Chen, Jintao and Qi, Chunjiao and Mao, Guobin and Liu, Yucheng},
  title = {Closed Cyclic DNA Machine for Sensitive Logic Operation and APE1 Detection},
  journal = {Small},
  year = {2023},
  volume = {19},
  number = {23},
  doi = {10.1002/smll.202207736}
}
Kostenlos starten →