AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Wearable Electroencephalography (EEG) devices enable home sleep monitoring but require systematic spectral validation before their physiological outputs can serve as proxies for polysomnographic features.

Aims

This study provides comprehensive spectral validation of the Zmax EEG headband against concurrent polysomnography (PSG) using the Wearanize+ dataset. Materials and Methods Seventy‐one participants with adequate signal quality underwent simultaneous home PSG and Zmax recording. Bandpower correspondence, calibration robustness, within‐subject reliability, lateralisation and spindle detection were evaluated across all sleep stages. Absolute delta power values reported in this study were computed using 4‐s Fast Fourier Transform windows and should not be directly compared to normative values derived from 8‐s windows because the shorter window introduces a systematic positive offset in the delta band that does not cancel in absolute comparisons.

Results

Zmax systematically underestimates bandpower across all frequency bands (bias −0.41 to −0.74 log units), attributable to the active Fpz reference electrode. A per‐subject N2‐referenced calibration eliminates this bias; N2 calibration outperformed N3 and rapid eye movement alternatives (mean post‐calibration r = 0.601 vs. 0.479 and 0.489). Post‐calibration spectral correspondence was strong for alpha (N3: r = 0.806) and sigma (N3: r = 0.752). Within‐subject reliability was excellent (split‐half r > 0.99).

Discussion

Demographic factors explained

Zitieren

APA

Parry, Y. D., & Briganti, G. (2026). Spectral validity and spindle detection of wearable frontal Electroencephalography: A per‐subject calibration framework and systematic validation against polysomnography using the Wearanize+ dataset. Sleep Research, 3(4), 337-347. https://doi.org/10.1002/slp2.70057

Vancouver

Parry YD, Briganti G. Spectral validity and spindle detection of wearable frontal Electroencephalography: A per‐subject calibration framework and systematic validation against polysomnography using the Wearanize+ dataset. Sleep Research. 2026;3(4):337-347. doi:10.1002/slp2.70057

BibTeX
@article{Parry2026,
  author = {Parry, Yildiz Dilara and Briganti, Giovanni},
  title = {Spectral validity and spindle detection of wearable frontal Electroencephalography: A per‐subject calibration framework and systematic validation against polysomnography using the Wearanize+ dataset},
  journal = {Sleep Research},
  year = {2026},
  volume = {3},
  number = {4},
  pages = {337--347},
  doi = {10.1002/slp2.70057}
}
Kostenlos starten →