Co−Fe‐based Heterometallo‐Supramolecular Polymer for Non‐Enzymatic Electrochemical Nitrite Detection and the Study of Electron Transfer Kinetics
ChemistrySelect · 04.04.2024 · 9 (13)
DOI: 10.1002/slct.202400623 ↗Kurz gefasst
Fachartikel in der Zeitschrift ChemistrySelect, online erschienen am 27.03.2024. Verfasst von Riva Akter und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 49 Literaturangaben.
Abstract (Originalsprache)
Here, we report the fabrication of Heterometallo‐supramolecular polymer (H‐SMP) for the selective oxidation of nitrite with the investigation of some kinetic parameters by the complex formation of Co(II) and Fe(II) salts with the symmetrical ligand which is composed of terpyridine moieties specially referred to as [4′,4′′′′‐(1,4‐Phenylene)bis(2,2′:6′,2′′‐terpyridine)] to form polyCoFe. The characterization of polyCoFe was carried out using UV‐Vis titration, FT‐IR and SEM. The viscosity measurement of H‐SMP was utilized to calculate its molecular weight using Mark‐Houwink‐Sakurada equation. The electrochemical performance of polyCoFe_GCE was evaluated using the CV and EIS techniques. The kinetics of the irreversible electro‐oxidation mechanism were investigated by introducing variations in scan‐rate and pH. The concurrence observed between the experimental and simulated CV results provided additional evidence supporting the accuracy and reliability of the determined kinetic parameters. We investigated the efficiency of polyCoFe_GCE for nitrite detection at various concentrations using CV as well as amperometry methods. The amperometric technique showed a wide linear range of 0.66 to 194.15 μM and a low detection limit of 0.11 μM. In addition, modified electrode underwent interference, stability, and reproducibility tests. Real samples were analyzed using both CV and amperometry methods, and the obtained results were compared with those obtained from standard solutions.
Zitieren
APA
Akter, R., Mia, M. M., Awal, A., Hossain, M. D., & Ahammad, A. J. S. (2024). Co−Fe‐based Heterometallo‐Supramolecular Polymer for Non‐Enzymatic Electrochemical Nitrite Detection and the Study of Electron Transfer Kinetics. ChemistrySelect, 9(13). https://doi.org/10.1002/slct.202400623
Vancouver
Akter R, Mia MM, Awal A, Hossain MD, Ahammad AJS. Co−Fe‐based Heterometallo‐Supramolecular Polymer for Non‐Enzymatic Electrochemical Nitrite Detection and the Study of Electron Transfer Kinetics. ChemistrySelect. 2024;9(13). doi:10.1002/slct.202400623
BibTeX
@article{Akter2024,
author = {Akter, Riva and Mia, Md. Mithu and Awal, Abdul and Hossain, Md. Delwar and Ahammad, A. J. Saleh},
title = {Co−Fe‐based Heterometallo‐Supramolecular Polymer for Non‐Enzymatic Electrochemical Nitrite Detection and the Study of Electron Transfer Kinetics},
journal = {ChemistrySelect},
year = {2024},
volume = {9},
number = {13},
doi = {10.1002/slct.202400623}
}
EUVIMED