Scaled average bioequivalence methods for highly variable drugs: Leveling‐off soft limits and the EMA's 2010 guideline (some ways to improve its type I error control)
Statistics in Medicine · 2024
DOI: 10.1002/sim.10021 ↗Kurz gefasst
Leitlinie in der Zeitschrift Statistics in Medicine, 2024. Verfasst von Joel Muñoz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Statistics, University of Concepcion, Concepcion, Chile. Hauptthemen laut MEDLINE: Therapeutic Equivalency. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: Spanish Ministerio de Ciencia e Innovación, Generalitat de Catalunya.
Abstract (Originalsprache)
The regulatory EMA's reference scaled average bioequivalence (RSABE) approach for highly variable drugs suffers from some type I error control problems at the neighborhood of the 30% coefficient of variation (CV), where the bioequivalence (BE) limits change from constant to linearly scaled. This paper analyses BE inference methods based on the “Leveling‐off” (LO) soft sigmoid expanding BE limits that were proposed as an appealing surrogate for the EMA's limits and compares both approaches, on the replicated and partially replicated crossover designs. The initially proposed version of the LO method also has type I error inflation problems, albeit attenuated. But given its more mathematically regular character, it is more suitable for analytical corrections. Here we introduce two improvements over LO, one based on the application of Howe's method and the other based on correcting the estimation error. They further reduce the type I error inflation, although it does not disappear completely. Finally, the effect of heteroscedasticity on the above results is studied. It leads to inflation or deflation of the type I error, depending on the design and the type of heteroscedasticity (variability of the test product greater than that of the reference product or the opposite). The replicated design is much more stable against these effects than the partially replicated design and maintains these improvements much better.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Statistics, University of Concepcion, Concepcion, Chile.
- Department of Genetics, Microbiology and Statistics, Statistics Section, Universitat de Barcelona, Barcelona, Spain.
- Faculty of Basic Sciences, University Catholic of Maule, Talca, Chile.
- Doctorate Program on Biomedicine, Universitat de Barcelona, Barcelona, Spain.
ORCID-Profile: Joel Muñoz
Förderung
- Spanish Ministerio de Ciencia e Innovación
- Generalitat de Catalunya
Zitieren
APA
Muñoz, J., Ocaña, J., Suárez, R., & Millapán, C. (2024). Scaled average bioequivalence methods for highly variable drugs: Leveling‐off soft limits and the EMA's 2010 guideline (some ways to improve its type I error control). Statistics in Medicine. https://doi.org/10.1002/sim.10021
Vancouver
Muñoz J, Ocaña J, Suárez R, Millapán C. Scaled average bioequivalence methods for highly variable drugs: Leveling‐off soft limits and the EMA's 2010 guideline (some ways to improve its type I error control). Statistics in Medicine. 2024. doi:10.1002/sim.10021
BibTeX
@article{Muoz2024,
author = {Muñoz, Joel and Ocaña, Jordi and Suárez, Rolando and Millapán, Carolina},
title = {Scaled average bioequivalence methods for highly variable drugs: Leveling‐off soft limits and the EMA's 2010 guideline (some ways to improve its type I error control)},
journal = {Statistics in Medicine},
year = {2024},
doi = {10.1002/sim.10021}
}
EUVIMED