P‐18.3: A Step‐Counting Circuit Module for Liquid Metal/PDMS Porous Sponge Gait Sensing Units
SID Symposium Digest of Technical Papers · 2026-08 · 57 (S1) · 2090-2092
DOI: 10.1002/sdtp.70003_561 ↗Kurz gefasst
Fachartikel in der Zeitschrift SID Symposium Digest of Technical Papers, online erschienen am 11.09.2026. Verfasst von Shijie Zhang und 6 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.
Abstract (Originalsprache)
This paper presents a dedicated step‐counting circuit module designed for liquid metal/PDMS porous sponge triboelectric nanogenerator (TENG) gait sensing units, addressing the challenges of irregular signal amplitude, low‐frequency output, and environmental noise inherent to these sensors. The proposed module integrates voltage scaling, AC‐to‐DC conversion, noise filtering, Schmitt‐trigger waveform shaping, monostable pulse generation, counting and decoding, display driving, and low‐power management into a compact and robust hardware architecture. The signal conditioning unit scales the high‐voltage AC output from the TENG sensor to safe CMOS logic levels, rectifies it into a unipolar signal, and suppresses high‐frequency noise through a two‐stage RC filter. A Schmitt‐trigger comparator converts the filtered signal into a clean square wave, which then triggers an NE555 monostable circuit to generate standardized pulses of fixed width, ensuring that each gait event is counted precisely. The pulses feed into a CD4026‐based decade counter with integrated 7‐segment decoding, which directly drives a common‐cathode LED display to visually indicate the step count. Experimental results demonstrate accurate step counting with a maximum error of one step per ten trials, stable waveform shaping, and low static power consumption, validating the effectiveness of the circuit in practical applications. The proposed module is suitable for integration into smart footwear, rehabilitation devices, and wearable gait monitoring systems, offering a low‐cost, low‐power, and noise‐immune hardware solution for real‐time step detection without requiring microcontroller‐based processing. This work provides a practical framework for enhancing the usability and commercialization potential of liquid metal/PDMS porous sponge TENG‐based gait sensors.
Zitieren
APA
Zhang, S., Chen, L., Ni, X., Liao, H., Zhang, A., Wang, Q., & Lin, J. (2026). P‐18.3: A Step‐Counting Circuit Module for Liquid Metal/PDMS Porous Sponge Gait Sensing Units. SID Symposium Digest of Technical Papers, 57(S1), 2090-2092. https://doi.org/10.1002/sdtp.70003_561
Vancouver
Zhang S, Chen L, Ni X, Liao H, Zhang A, Wang Q, et al. P‐18.3: A Step‐Counting Circuit Module for Liquid Metal/PDMS Porous Sponge Gait Sensing Units. SID Symposium Digest of Technical Papers. 2026;57(S1):2090-2092. doi:10.1002/sdtp.70003_561
BibTeX
@article{Zhang2026,
author = {Zhang, Shijie and Chen, Luoyi and Ni, Xinyi and Liao, Hongwei and Zhang, Anxin and Wang, Qiyao and Lin, Jianpu},
title = {P‐18.3: A Step‐Counting Circuit Module for Liquid Metal/PDMS Porous Sponge Gait Sensing Units},
journal = {SID Symposium Digest of Technical Papers},
year = {2026},
volume = {57},
number = {S1},
pages = {2090--2092},
doi = {10.1002/sdtp.70003_561}
}
EUVIMED