86‐3: The Pad Structure design to improve the success rate of Cell Test
SID Symposium Digest of Technical Papers · 2026-08 · 57 (S1) · 862-863
DOI: 10.1002/sdtp.70003_231 ↗Kurz gefasst
Fachartikel in der Zeitschrift SID Symposium Digest of Technical Papers, online erschienen am 11.09.2026. Verfasst von Tingting Zhang und 7 weiteren Autor:innen. Die Arbeit nennt 2 Literaturangaben.
Abstract (Originalsprache)
During panel Cell Test, poor contact between the golden fingers and the top‐layer metal of the panel pad leads to a high‐impedance signal state. This article describes a method of increasing the thickness of the top metal layer of the panel pad by stacking underlying metal layers, thereby reducing the height difference between the golden fingers and the panel pad metal, and ultimately increasing the contact overlap area. The new pad structure can greatly improve the success rate of one‐time crimping.
Zitieren
APA
Zhang, T., Yao, L., Wang, H., Hu, S., Li, W., Wu, Y., Gao, X., & Shen, Y. (2026). 86‐3: The Pad Structure design to improve the success rate of Cell Test. SID Symposium Digest of Technical Papers, 57(S1), 862-863. https://doi.org/10.1002/sdtp.70003_231
Vancouver
Zhang T, Yao L, Wang H, Hu S, Li W, Wu Y, et al. 86‐3: The Pad Structure design to improve the success rate of Cell Test. SID Symposium Digest of Technical Papers. 2026;57(S1):862-863. doi:10.1002/sdtp.70003_231
BibTeX
@article{Zhang2026,
author = {Zhang, Tingting and Yao, Lei and Wang, Huan and Hu, Siming and Li, Weilong and Wu, Yong and Gao, Xiaoyu and Shen, Ying},
title = {86‐3: The Pad Structure design to improve the success rate of Cell Test},
journal = {SID Symposium Digest of Technical Papers},
year = {2026},
volume = {57},
number = {S1},
pages = {862--863},
doi = {10.1002/sdtp.70003_231}
}