Evaluation of passive flux samplers with different orifice sizes to measure ammonia volatilization losses
Soil Science Society of America Journal · 2023-09 · 87 (5) · 1109-1119
DOI: 10.1002/saj2.20567 ↗Kurz gefasst
Fachartikel in der Zeitschrift Soil Science Society of America Journal, online erschienen am 26.07.2023. Verfasst von Miguel L. Cabrera und 2 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
A common passive sampler used to measure NH 3 volatilization losses in field studies has a nozzle with a 1‐mm, round orifice that reduces air flow to increase NH 3 adsorption. This reduction in air flow, measured by the orifice's K value (0–1), implies a reduction in the amount of NH 3 entering the sampler per unit of time, which may require a longer exposure to accumulate measurable quantities of NH 3 . Increasing the diameter of the orifice would increase the NH 3 entering the sampler and possibly allow shorter exposure times, but it may also lead to increased NH 3 bypass. The objectives of this research were to (1) determine the effect of wind speed on NH 3 bypass in samplers with 1‐ or 2‐mm orifices, (2) determine the reduction in air speed in samplers with 1‐ or 2‐mm orifices by determining their K values, and (3) compare field NH 3 volatilization losses measured with 1‐ and 2‐mm orifices. A laboratory study with wind speeds ranging from 0.6 to 10 m·s −1 showed that both orifice sizes had NH 3 bypass at low and high wind speeds. Results from wind tunnel studies determined that flow was reduced to 63% ( K = 0.63) in 1‐mm orifices and to 74% ( K = 0.74) in 2‐mm orifices. Field studies indicated that 1‐mm orifices may measure greater NH 3 volatilization losses than 2‐mm orifices at average low wind speeds when maximum wind speeds 10 m·s −1 .
Zitieren
APA
Cabrera, M. L., Noor, N., & Moore, L. (2023). Evaluation of passive flux samplers with different orifice sizes to measure ammonia volatilization losses. Soil Science Society of America Journal, 87(5), 1109-1119. https://doi.org/10.1002/saj2.20567
Vancouver
Cabrera ML, Noor N, Moore L. Evaluation of passive flux samplers with different orifice sizes to measure ammonia volatilization losses. Soil Science Society of America Journal. 2023;87(5):1109-1119. doi:10.1002/saj2.20567
BibTeX
@article{Cabrera2023,
author = {Cabrera, Miguel L. and Noor, Nadia and Moore, Logan},
title = {Evaluation of passive flux samplers with different orifice sizes to measure ammonia volatilization losses},
journal = {Soil Science Society of America Journal},
year = {2023},
volume = {87},
number = {5},
pages = {1109--1119},
doi = {10.1002/saj2.20567}
}
EUVIMED