Comparative Evaluation of Two Microfluidic Sperm Sorting Devices: Laboratory Assessment of Sperm Quality and Retrospective Analysis of Embryological Outcomes Following Intracytoplasmic Sperm Injection
Reproductive Medicine and Biology · 2026-01 · 25 (1)
DOI: 10.1002/rmb2.70010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Reproductive Medicine and Biology, online erschienen am 08.01.2026. Verfasst von Ryota Tachibana und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center of Advanced Reproductive Medicine Mie University Hospital Tsu Mie Japan. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Purpose
Density gradient centrifugation (DGC) enriches motile sperm but may increase sperm DNA fragmentation (SDF), whereas microfluidic sperm sorting devices, such as ZyMōt and CA0, enable centrifugation‐free selection with lower SDF. Direct comparisons are limited, and their relative clinical efficacy remains unclear. We compared sperm parameters and SDF after DGC, ZyMōt, and CA0 to evaluate sperm selection performance and assessed the clinical utility of ZyMōt and CA0 based on intracytoplasmic sperm injection (ICSI) outcomes.
Methods
Seventeen semen samples were aliquoted into three groups and processed using DGC, ZyMōt, or CA0. Sperm parameters and SDF were evaluated before and after selection. ICSI was performed using ZyMōt or CA0‐selected sperm, inseminating 108 oocytes with ZyMōt and 64 with CA0, followed by the comparative analysis of embryo development.
Results
ZyMōt‐selected sperm exhibited higher motility, average path velocity, and amplitude of lateral head displacement than DGC ( p < 0.01); CA0‐selected sperm showed higher linearity and wobble. ZyMōt achieved higher rates of fertilization, blastocyst formation, and good‐quality blastocysts, and a lower percentage of poor‐quality cleavage‐stage embryos than CA0 (all p < 0.05).
Conclusions
ZyMōt demonstrated superior sperm quality compared with DGC and CA0, and favorable ICSI outcomes further support its potential clinical applicability. Trial Registration The study (H2023‐230) was registered in the Japan Registry of Clinical Trials (jRCT) Clinical Trials Registry in Japan (jRCT1040230045)
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center of Advanced Reproductive Medicine Mie University Hospital Tsu Mie Japan.
- Department of Obstetrics and Gynecology, Graduate School of Medicine Mie University Tsu Mie Japan.
- Obstetrics and Gynecology Mie University Hospital Tsu Mie Japan.
ORCID-Profile: Hiroki Takeuchi, Eiji Kondo
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Tachibana, R., Takeuchi, H., Yotsutani, M., Nishioka, M., Takayama, E., & Kondo, E. (2026). Comparative Evaluation of Two Microfluidic Sperm Sorting Devices: Laboratory Assessment of Sperm Quality and Retrospective Analysis of Embryological Outcomes Following Intracytoplasmic Sperm Injection. Reproductive Medicine and Biology, 25(1). https://doi.org/10.1002/rmb2.70010
Vancouver
Tachibana R, Takeuchi H, Yotsutani M, Nishioka M, Takayama E, Kondo E. Comparative Evaluation of Two Microfluidic Sperm Sorting Devices: Laboratory Assessment of Sperm Quality and Retrospective Analysis of Embryological Outcomes Following Intracytoplasmic Sperm Injection. Reproductive Medicine and Biology. 2026;25(1). doi:10.1002/rmb2.70010
BibTeX
@article{Tachibana2026,
author = {Tachibana, Ryota and Takeuchi, Hiroki and Yotsutani, Miyu and Nishioka, Mikiko and Takayama, Erina and Kondo, Eiji},
title = {Comparative Evaluation of Two Microfluidic Sperm Sorting Devices: Laboratory Assessment of Sperm Quality and Retrospective Analysis of Embryological Outcomes Following Intracytoplasmic Sperm Injection},
journal = {Reproductive Medicine and Biology},
year = {2026},
volume = {25},
number = {1},
doi = {10.1002/rmb2.70010}
}
EUVIMED