EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Robotic‐Assisted Bile Duct Cannulation During Endoscopic Retrograde Cholangiopancreatography: A Randomised Controlled Crossover Animal Study

Bin Yan, Yongming Yang, Lihua Peng, Yuhang Zhang, Zhifeng Zhao, Mengyuan Liu, Xiuli Zhang, Gang Sun iD, Zikai Wang, Fei Pan, Peng Wang, Yaning Li und 6 weitere

The International Journal of Medical Robotics and Computer Assisted Surgery · 2026

DOI: 10.1002/rcs.70174 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2026. Verfasst von Bin Yan und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China. Hauptthemen laut MEDLINE: Bile Ducts, Catheterization, Cholangiopancreatography, Endoscopic Retrograde, Robotic Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Science and Technology Planning Project, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Endoscopic retrograde cholangiopancreatography (ERCP) is technically challenging, with high operator radiation exposure, physical strain, and a steep learning curve, necessitating a robotic solution. This study evaluated robotic‐assisted ERCP feasibility and efficacy in an animal model.

Methods

In this randomised controlled crossover study, three experienced endoscopists performed 24 ERCP procedures (12 robotic‐assisted vs. 12 manual) on four beagles using the YunSRobot system. Primary outcomes included papilla positioning maintenance, cannulation time, and success rate.

Results

Robotic‐assisted ERCP demonstrated superior papilla positioning (95.74% vs. 77.25%, p < 0.01), indicating more endoscopic stability during cannulation. The successful cannulation rate was identical in both groups (83.3%). The robotic group required fewer attempts (2.0 vs. 3.5) and experienced no scope dislocations (0 vs. 5). No severe adverse events occurred in either group.

Conclusions

Robotic‐assisted ERCP is feasible, safe, and effective, offering significantly improved endoscopic stability with comparable cannulation success to manual techniques.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bile DuctsCatheterizationCholangiopancreatography, Endoscopic RetrogradeRobotic Surgical ProceduresAnimalsDogsFemaleMaleCross-Over StudiesFeasibility Studies

Stichwörter der Autor:innen

YunSRobotendoscopic retrograde cholangiopancreatographyendoscopic stabilityrobotic‐assisted

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China.
  • State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China.
  • China Medical University, Shenyang, China.
  • Department of Statistics and Epidemiology, Graduate School of Chinese PLA General Hospital, Beijing, China.
  • National Clinical Research Center for Geriatric Diseases, Chinese PLA General Hospital, Beijing, China.

ORCID-Profile: Gang Sun, Hao Liu

Förderung

  • National Science and Technology Planning Project
  • National Key Research and Development Program of China

Zitieren

APA

Yan, B., Yang, Y., Peng, L., Zhang, Y., Zhao, Z., Liu, M., Zhang, X., Sun, G., Wang, Z., Pan, F., Wang, P., Li, Y., Zhang, S., Liu, M., Zhang, X., Yan, J., Liu, H., & Yang, Y. (2026). Robotic‐Assisted Bile Duct Cannulation During Endoscopic Retrograde Cholangiopancreatography: A Randomised Controlled Crossover Animal Study. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70174

Vancouver

Yan B, Yang Y, Peng L, Zhang Y, Zhao Z, Liu M, et al. Robotic‐Assisted Bile Duct Cannulation During Endoscopic Retrograde Cholangiopancreatography: A Randomised Controlled Crossover Animal Study. The International Journal of Medical Robotics and Computer Assisted Surgery. 2026. doi:10.1002/rcs.70174

BibTeX
@article{Yan2026,
  author = {Yan, Bin and Yang, Yongming and Peng, Lihua and Zhang, Yuhang and Zhao, Zhifeng and Liu, Mengyuan and Zhang, Xiuli and Sun, Gang and Wang, Zikai and Pan, Fei and Wang, Peng and Li, Yaning and Zhang, Shenglin and Liu, Miao and Zhang, Xiaomei and Yan, Jingshuang and Liu, Hao and Yang, Yunsheng},
  title = {Robotic‐Assisted Bile Duct Cannulation During Endoscopic Retrograde Cholangiopancreatography: A Randomised Controlled Crossover Animal Study},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2026},
  doi = {10.1002/rcs.70174}
}
Kostenlos starten →