Robotic Spleen‐Preserving Distal Pancreatectomy: Perioperative Outcomes and Comparison of Two Energy Devices
The International Journal of Medical Robotics and Computer Assisted Surgery · 2026-04 · 22 (2)
DOI: 10.1002/rcs.70170 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, online erschienen am 26.04.2026. Verfasst von Yusheng Du und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pancreatic Surgery, The First Affiliated Hospital of Xuzhou Medical University, Xuzhou, China. Hauptthemen laut MEDLINE: Pancreatectomy, Robotic Surgical Procedures, Spleen, Organ Sparing Treatments. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
Background
We evaluated the perioperative outcomes of robotic spleen‐preserving distal pancreatectomy (RSPDP) and compared articulated monopolar curved scissors (R‐MCS) with the harmonic scalpel (R‐HS) as the primary energy device.
Methods
We retrospectively reviewed consecutive single‐centre RSPDPs (September 2020‐August 2025) and compared baseline characteristics, intraoperative variables, and postoperative outcomes.
Results
Sixty‐nine patients were included (R‐MCS, n = 31; R‐HS, n = 38). Overall spleen preservation was 79.7%, with no between‐group difference (80.6% vs. 78.9%, p = 0.852). Among spleen‐preserved cases, Kimura completion was higher with R‐MCS (88.0% vs. 66.7%, p = 0.032). Operative time and blood loss were comparable. Time to first flatus was shorter with R‐MCS (3.2 ± 0.9 vs. 3.7 ± 0.7 days, p = 0.014). Overall complications occurred in 18.8%, including clinically relevant postoperative pancreatic fistula in 11.6%; no Clavien‐Dindo grade ≥ IIIb complications or perioperative mortality occurred.
Conclusion
RSPDP is safe and feasible. R‐MCS may improve Kimura completion and modestly shorten the time to first flatus, pending further validation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pancreatic Surgery, The First Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.
ORCID-Profile: Wenxing Zhao
Zitieren
APA
Du, Y., Wang, J., Liu, L., Ma, H., Li, Y., & Zhao, W. (2026). Robotic Spleen‐Preserving Distal Pancreatectomy: Perioperative Outcomes and Comparison of Two Energy Devices. The International Journal of Medical Robotics and Computer Assisted Surgery, 22(2). https://doi.org/10.1002/rcs.70170
Vancouver
Du Y, Wang J, Liu L, Ma H, Li Y, Zhao W. Robotic Spleen‐Preserving Distal Pancreatectomy: Perioperative Outcomes and Comparison of Two Energy Devices. The International Journal of Medical Robotics and Computer Assisted Surgery. 2026;22(2). doi:10.1002/rcs.70170
BibTeX
@article{Du2026,
author = {Du, Yusheng and Wang, Ji and Liu, Li and Ma, Hongqin and Li, Ying and Zhao, Wenxing},
title = {Robotic Spleen‐Preserving Distal Pancreatectomy: Perioperative Outcomes and Comparison of Two Energy Devices},
journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
year = {2026},
volume = {22},
number = {2},
doi = {10.1002/rcs.70170}
}