Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, online erschienen am 31.03.2026. Verfasst von Tanjing Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of High Efficiency and Clean Mechanical Manufacture (Ministry of Education), School of Mechanical Engineering, Shandong University, Ji…. Hauptthemen laut MEDLINE: Algorithms, Robotic Surgical Procedures, Tremor. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Key Technology Research and Development Program of Shandong Province.
Abstract (Originalsprache)
Background
Master follower surgical robotic systems are widely used in invasive procedures but remain vulnerable to end effector tremor transmitted from the operator's physiological tremor, reducing precision.
Methods
Physiological tremor was characterised with a three‐dimensional optical motion capture system and integrated into master follower control strategy enhanced with Kalman filter based tremor suppression algorithm. The method was validated on a custom platform using 24 predefined motion trajectories executed via a force feedback haptic master and robotic slave manipulator.
Results
Physiological tremor exhibited amplitudes that did not exceed 1 mm and dominant frequencies within 5–15 Hz. Across all 24 motion sets, suppression significantly reduced in majority of cases standard deviations of end‐effector velocity and acceleration and removed high‐frequency components while preserving smooth motion.
Conclusions
The Kalman filter based master follower tremor suppression strategy provides accurate and effective attenuation of physiological tremors, enhancing the precision, stability and operational safety of surgical robotic manipulation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture (Ministry of Education), School of Mechanical Engineering, Shandong University, Jinan, China.
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
- JIER Machine-Tool Group Co. LTD, Jinan, China.
- National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan, China.
- The Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, China.
ORCID-Profile: Tanjing Zhang, Xianzheng Zhou
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- Key Technology Research and Development Program of Shandong Province
- Natural Science Foundation of Shandong Province
Zitieren
APA
Zhang, T., Sun, C., Zhou, X., Chen, Y., Yue, X., & Bi, J. (2026). A Tremor Suppression Method for the Master–Follower Surgical Robot Manipulator Based on Kalman Filter Algorithm. The International Journal of Medical Robotics and Computer Assisted Surgery, 22(2). https://doi.org/10.1002/rcs.70159
Vancouver
Zhang T, Sun C, Zhou X, Chen Y, Yue X, Bi J. A Tremor Suppression Method for the Master–Follower Surgical Robot Manipulator Based on Kalman Filter Algorithm. The International Journal of Medical Robotics and Computer Assisted Surgery. 2026;22(2). doi:10.1002/rcs.70159
BibTeX
@article{Zhang2026,
author = {Zhang, Tanjing and Sun, Congyu and Zhou, Xianzheng and Chen, Yimiao and Yue, Xiaoming and Bi, Jianping},
title = {A Tremor Suppression Method for the Master–Follower Surgical Robot Manipulator Based on Kalman Filter Algorithm},
journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
year = {2026},
volume = {22},
number = {2},
doi = {10.1002/rcs.70159}
}
EUVIMED