EUVIMEDEUVIMED entdecken
Crossref

Sensorless Transparency Optimised Force Safety Guarantee Mechanism for Robot‐Assisted Minimally Invasive Surgery

Fang Huang, Hongqiang Sang iD, Fen Liu, Rui Han

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025-04 · 21 (2)

DOI: 10.1002/rcs.70060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, online erschienen am 13.03.2025. Verfasst von Fang Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Tiangong University, Tianjin, China. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Minimally Invasive Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Compared with traditional open surgery, robotic‐assisted minimally invasive surgery lacks force sensing ability.

Methods

A sensorless transparency optimised force safety mechanism is put forward to improve the external force safety of the surgical robot in this paper. An improved fixed‐time indirect adaptive fuzzy controller is proposed to approximate the unknown uncertainties in the dynamics of the patient‐side manipulator. An online force simulation controller is designed based on the hierarchical force.

Results

Simulations and experiments demonstrate that the designed fixed‐time indirect adaptive fuzzy controller exhibits excellent performance in trajectory tracking, fixed‐time convergence, fuzzy approximation, and smooth control input. In addition, the online force simulation controller effectively decreases the force in the potentially unsafe area, thereby inhibiting the unsafe force.

Conclusions

This mechanism offers potential applications to improve the safety of external forces for the sensorless surgical robots.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresMinimally Invasive Surgical ProceduresHumansComputer SimulationFuzzy LogicEquipment DesignAlgorithmsRobotics

Stichwörter der Autor:innen

indirect fuzzy controlonline force simulation controllerrobot‐assisted minimally invasive surgerysensorless transparency optimised

Autor:innen und Institutionen

  • School of Mechanical Engineering, Tiangong University, Tianjin, China.
  • Tianjin Key Laboratory of Advanced Mechatronic Equipment Technology, Tiangong University, Tianjin, China.

ORCID-Profile: Hongqiang Sang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Huang, F., Sang, H., Liu, F., & Han, R. (2025). Sensorless Transparency Optimised Force Safety Guarantee Mechanism for Robot‐Assisted Minimally Invasive Surgery. The International Journal of Medical Robotics and Computer Assisted Surgery, 21(2). https://doi.org/10.1002/rcs.70060

Vancouver

Huang F, Sang H, Liu F, Han R. Sensorless Transparency Optimised Force Safety Guarantee Mechanism for Robot‐Assisted Minimally Invasive Surgery. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025;21(2). doi:10.1002/rcs.70060

BibTeX
@article{Huang2025,
  author = {Huang, Fang and Sang, Hongqiang and Liu, Fen and Han, Rui},
  title = {Sensorless Transparency Optimised Force Safety Guarantee Mechanism for Robot‐Assisted Minimally Invasive Surgery},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  volume = {21},
  number = {2},
  doi = {10.1002/rcs.70060}
}
Kostenlos starten →