EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Autonomous Establishment of CT‐Independent Sections to Obtain Optimum Pedicle‐Screw Axis in Direction, Length, and Safety Margin

Amit Kumar iD, Dwarakanath T A iD, Gaurav Bhutani, Dwarakanath Srinivas

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025

DOI: 10.1002/rcs.70049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Amit Kumar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Robotics Handling and Robotics, Homi Bhabha National Institute, Mumbai, India. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Spinal Fusion, Pedicle Screws, Robotic Surgical Procedures. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate perception of pedicle geometry during pedicle‐screw placement surgery is critically important because the margin‐for‐error is small.

Method

An assessment algorithm is developed to provide machine‐independent MultiPlanar Reconstruction (MiMPR) of the pedicle. The reconstruction is independent of the CT‐machine frame and enhances patient data portability. Additionally, the algorithm obtains the pedicle‐screw axis with optimum direction, length, and margin using MPRs. A method for the autonomous identification of four body features to form a CT‐independent vertebral frame, {V}, in the image space is formulated.

Result

Applied to 200 high‐resolution CT images, the approach achieved a 100% success rate in defining the pedicle‐medial axis and maximum screw diameter considering the safety margin of 2 mm.

Conclusions

The method eliminates subjective assessment. It provides objective assessment in determining the pedicle‐medial axis with optimal direction and margin without human annotation. Additionally, it significantly enhances screw placement accuracy in robot‐assisted spinal fusion surgeries, regardless of vertebra orientation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedSpinal FusionPedicle ScrewsRobotic Surgical ProceduresSurgery, Computer-AssistedHumansAlgorithmsSpineImage Processing, Computer-AssistedLumbar Vertebrae

Stichwörter der Autor:innen

machine‐independent sectionspatient data portabilitypedicle‐medial axispedicle‐screw pathrobotic spine surgeryspinal fixationvertebral coordinate system

Autor:innen und Institutionen

  • Division of Robotics Handling and Robotics, Homi Bhabha National Institute, Mumbai, India.
  • Department of Neurosurgical Oncology, Tata Memorial Centre, Mumbai, India.
  • Division of Robotics Handling and Robotics, Bhabha Atomic Research Centre, Mumbai, India.
  • Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bengaluru, India.

ORCID-Profile: Amit Kumar, Dwarakanath T A

Zitieren

APA

Kumar, A., T A, D., Bhutani, G., & Srinivas, D. (2025). Autonomous Establishment of CT‐Independent Sections to Obtain Optimum Pedicle‐Screw Axis in Direction, Length, and Safety Margin. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70049

Vancouver

Kumar A, T A D, Bhutani G, Srinivas D. Autonomous Establishment of CT‐Independent Sections to Obtain Optimum Pedicle‐Screw Axis in Direction, Length, and Safety Margin. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70049

BibTeX
@article{Kumar2025,
  author = {Kumar, Amit and T A, Dwarakanath and Bhutani, Gaurav and Srinivas, Dwarakanath},
  title = {Autonomous Establishment of CT‐Independent Sections to Obtain Optimum Pedicle‐Screw Axis in Direction, Length, and Safety Margin},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70049}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche