EUVIMEDEUVIMED entdecken
Crossref

Robot‐assisted total knee arthroplasty system provides more precise control of the femoral rotation angle: A retrospective study

Peng Yan, Xudong Duan, Yutian Lei, Fangze Xing, Ruomu Cao, Sen Luo, Yang Chen, Zeyu Liu, Kunzheng Wang, Pei Yang iD, Run Tian

The International Journal of Medical Robotics and Computer Assisted Surgery · 2024

DOI: 10.1002/rcs.2635 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2024. Verfasst von Peng Yan und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Femur. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Rotational alignment in total knee arthroplasty (TKA) is a crucial technical point that needs attention. We conducted a retrospective study to investigate whether a new robot‐assisted TKA (RA‐TKA) could improve the accuracy of rotational alignment and whether rotational alignment affects postoperative pain and functional evaluation of the knee.

Methods

A total of 136 consecutive patients who underwent TKA were included in this study. Half of the patients underwent RA‐TKA and the other half underwent conventional TKA (CON‐TKA) by the same group of surgeons. Collect the relevant parameters.

Results

The postoperative femoral rotation angle (FRA) was −0.72 ± 2.59° in the robot‐assisted group and 1.13 ± 2.73° in the conventional group, and were statistically significantly different ( p < 0.001).

Conclusion

This study provides preliminary evidence that the RA‐TKA provides more precise control of FRA than CON‐TKA, and verifies that tibial rotation angle and combined rotation angle affect postoperative knee pain and functional evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresFemurHumansRetrospective StudiesFemaleMaleAgedMiddle AgedRotationKnee JointRange of Motion, ArticularPostoperative PainTreatment Outcome

Stichwörter der Autor:innen

roboticsrotational alignmenttotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.

ORCID-Profile: Pei Yang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Yan, P., Duan, X., Lei, Y., Xing, F., Cao, R., Luo, S., Chen, Y., Liu, Z., Wang, K., Yang, P., & Tian, R. (2024). Robot‐assisted total knee arthroplasty system provides more precise control of the femoral rotation angle: A retrospective study. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.2635

Vancouver

Yan P, Duan X, Lei Y, Xing F, Cao R, Luo S, et al. Robot‐assisted total knee arthroplasty system provides more precise control of the femoral rotation angle: A retrospective study. The International Journal of Medical Robotics and Computer Assisted Surgery. 2024. doi:10.1002/rcs.2635

BibTeX
@article{Yan2024,
  author = {Yan, Peng and Duan, Xudong and Lei, Yutian and Xing, Fangze and Cao, Ruomu and Luo, Sen and Chen, Yang and Liu, Zeyu and Wang, Kunzheng and Yang, Pei and Tian, Run},
  title = {Robot‐assisted total knee arthroplasty system provides more precise control of the femoral rotation angle: A retrospective study},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2024},
  doi = {10.1002/rcs.2635}
}
Kostenlos starten →