Transformer‐based 2D/3D medical image registration for X‐ray to CT via anatomical features
The International Journal of Medical Robotics and Computer Assisted Surgery · 2024
DOI: 10.1002/rcs.2619 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2024. Verfasst von Feng Qu und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China. Hauptthemen laut MEDLINE: Algorithms, Imaging, Three-Dimensional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Zhongshan Social Welfare and Basic Research Project.
Abstract (Originalsprache)
Background
2D/3D medical image registration is one of the key technologies for surgical navigation systems to perform pose estimation and achieve accurate positioning, which still remains challenging. The purpose of this study is to introduce a new method for X‐ray to CT 2D/3D registration and conduct a feasibility study.
Methods
In this study, a 2D/3D affine registration method based on feature point detection is investigated. It combines the morphological and edge features of spinal images to accurately extract feature points from the images, and uses graph neural networks to aggregate anatomical features of different points to increase the local detail information. Meanwhile, global and positional information are extracted by the Swin Transformer.
Results
The results indicate that the proposed method has shown improvements in both accuracy and success ratio compared with other methods. The mean target registration error value reached up to 0.31 mm; meanwhile, the runtime overhead was much lower, achieving an average runtime of about 0.6 s. This ultimately improves the registration accuracy and efficiency, demonstrating the effectiveness of the proposed method.
Conclusions
The proposed method can provide more comprehensive image information and shows good prospects for pose estimation and achieving accurate positioning in surgical navigation systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China.
- Research Center for Medical Image Computing, Zhongshan Institute of Changchun University of Science and Technology, Zhongshan, China.
Förderung
- Zhongshan Social Welfare and Basic Research Project
Zitieren
APA
Qu, F., Zhang, M., Shi, W., He, W., & Jiang, Z. (2024). Transformer‐based 2D/3D medical image registration for X‐ray to CT via anatomical features. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.2619
Vancouver
Qu F, Zhang M, Shi W, He W, Jiang Z. Transformer‐based 2D/3D medical image registration for X‐ray to CT via anatomical features. The International Journal of Medical Robotics and Computer Assisted Surgery. 2024. doi:10.1002/rcs.2619
BibTeX
@article{Qu2024,
author = {Qu, Feng and Zhang, Min and Shi, Weili and He, Wei and Jiang, Zhengang},
title = {Transformer‐based 2D/3D medical image registration for X‐ray to CT via anatomical features},
journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
year = {2024},
doi = {10.1002/rcs.2619}
}
EUVIMED