Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report
Respirology Case Reports · 2026-11 · 14 (11)
DOI: 10.1002/rcr2.70817 ↗Kurz gefasst
Fallbericht in der Zeitschrift Respirology Case Reports, online erschienen am 09.11.2026. Verfasst von Daisuke Kinose und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Respiratory Medicine Shiga University of Medical Science Otsu Shiga Japan. Die Arbeit nennt 6 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A 75‐year‐old man with chronic obstructive pulmonary disease underwent endobronchial valve (EBV) placement in the left lower lobe and expectorated the valve from left B10 1 month later. Retrospective analysis of preprocedural dynamic computed tomography (CT) images showed that the median B10 luminal diameter increased from 4.25 mm at end‐expiration to 6.55 mm at end‐inspiration, approaching the upper limit of the recommended working range (4.0–7.0 mm) for the initially placed size 4.0 valve. A size 5.5 valve was subsequently placed without further expectoration. Bronchoscopic sizing under general anaesthesia with neuromuscular blockade and positive‐pressure ventilation may underestimate the maximum airway calibre encountered during spontaneous breathing, particularly in dependent bronchi. Inspiratory CT‐based airway assessment may provide useful complementary information for planning EBV placement and selecting an appropriate valve size.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Respiratory Medicine Shiga University of Medical Science Otsu Shiga Japan.
- Department of Radiology Shiga University of Medical Science Otsu Shiga Japan.
- Health Administration Center Shiga University of Medical Science Otsu Shiga Japan.
ORCID-Profile: Daisuke Kinose, Hiroaki Nakagawa, Masafumi Yamaguchi, Yasutaka Nakano
Zitieren
APA
Kinose, D., Nagatani, Y., Nakagawa, H., Fujino, M., Ichida, A., Tanaka, R., Okuda, S., Ueki, Y., Misonou, M., Yamazaki, A., Ogawa, E., Yamaguchi, M., & Nakano, Y. (2026). Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report. Respirology Case Reports, 14(11). https://doi.org/10.1002/rcr2.70817
Vancouver
Kinose D, Nagatani Y, Nakagawa H, Fujino M, Ichida A, Tanaka R, et al. Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report. Respirology Case Reports. 2026;14(11). doi:10.1002/rcr2.70817
BibTeX
@article{Kinose2026,
author = {Kinose, Daisuke and Nagatani, Yukihiro and Nakagawa, Hiroaki and Fujino, Mayu and Ichida, Amane and Tanaka, Reo and Okuda, Shogo and Ueki, Yasumitsu and Misonou, Masashi and Yamazaki, Akio and Ogawa, Emiko and Yamaguchi, Masafumi and Nakano, Yasutaka},
title = {Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography‐Based Airway Sizing—A Case Report},
journal = {Respirology Case Reports},
year = {2026},
volume = {14},
number = {11},
doi = {10.1002/rcr2.70817}
}
EUVIMED